1-Year Clinical Outcomes of All Comers Treated With 2 Bioresorbable Polymer-Coated Sirolimus-Eluting Stents: Propensity Score–Matched Comparison of the COMBO and Ultrathin-Strut Orsiro Stents

J. Chandrasekhar, M.M. Kok, D.N. Kalkman, M.B. Aquino, P. Zocca, P. Woudstra, M.A. Beijk, L.S. Kerkmeijer, S. Sartori, U. Baber, J.G. Tijssen, K.T. Koch, G.D. Dangas, A. Colombo, S. Pocock, C. von Birgelen, R. Mehran, R.J. de Winter, L.C. van der Heijden, P.W. DanseC.E. Schotborgh, M. Scholte, M.T. Joe Gin, S. Somi, K.G. van Houwelingen, M.G. Stoel, F.H.A.F. de Man, J.H.W. Louwerenburg, M. Hartmann, G.C.M. Linssen, J. van der Palen, C.J.M. Doggen, M.M. Löwik

Research output: Contribution to journalArticleAcademicpeer-review

11 Citations (Scopus)
52 Downloads (Pure)
Original languageEnglish
Pages (from-to)820-830
JournalJACC: Cardiovascular Interventions
Volume13
Issue number7
DOIs
Publication statusPublished - 13 Apr 2020