4D Dynamic Contrast-Enhanced Breast CT: Evaluation of quantitative accuracy

Juan J. Pautasso, Mikhail Mikerov, Liselot Goris, Koen Michielsen, Ioannis Sechopoulos

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

31 Downloads (Pure)

Abstract

Four-dimensional dynamic contrast-enhanced breast CT (4D DCE-bCT) holds potential for high spatio-temporalresolution imaging for characterization and monitoring of breast tumors. This study presents a dedicated phantom-based evaluation of the accuracy of dynamic iodine concentration quantification in 4D DCE-bCT. A breast CT (bCT) system was adapted for extended acquisition times, and the x-ray spectrum was optimized (65 kV/0.25 mm Cu). Additionally, reconstruction and correction algorithms were developed for accurate iodine quantification. The imaging sequence involved a 10-second pre-contrast scan with 360 projections, followed by two 100-second post-contrast scans, each with 400 projection images over 10 rotations, with 10 seconds between each scan. In this experiment, we aimed to quantitatively assess the changes in iodine concentration, while a time-varying concentration of iodine (range 0.5 to 10 mg I/mL) was pumped through a 5 mm diameter tube in an olive-oil breast phantom. Pre- and post-contrast images were scatter-corrected and reconstructed using a polychromatic iterative reconstruction (IMPACT) combined with PICCS. This process yielded a 38-framevirtual monoenergetic (30 keV) image sequence at 5-second intervals. To verify the perfusion curve accuracy, a 5 × 5 × 10 voxel VOI was compared against the known true iodine concentration. Linear fits to the results showed good precision with some under-estimation of the true concentration (wash-in: slope = 0.7530, offset = +0.5208, R2 = 0.985; wash-out: slope = 1.012, offset = -0.8295, R2 = 0.987). These findings indicate the 4D DCE-bCT's potential to provide quantitatively accurate estimates of iodine concentration.

Original languageEnglish
Title of host publication17th International Workshop on Breast Imaging, IWBI 2024
EditorsMaryellen L. Giger, Heather M. Whitney, Karen Drukker, Hui Li
PublisherSPIE
ISBN (Electronic)9781510680203
DOIs
Publication statusPublished - 29 May 2024
Event17th International Workshop on Breast Imaging, IWBI 2024 - Chicago, United States
Duration: 9 Jun 202412 Jun 2024
Conference number: 17

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume13174
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

Conference17th International Workshop on Breast Imaging, IWBI 2024
Abbreviated titleIWBI 2024
Country/TerritoryUnited States
CityChicago
Period9/06/2412/06/24

Keywords

  • 2024 OA procedure
  • Iodine quantification
  • Perfusion accuracy
  • 4D dynamic contrast-enhanced breast CT

Fingerprint

Dive into the research topics of '4D Dynamic Contrast-Enhanced Breast CT: Evaluation of quantitative accuracy'. Together they form a unique fingerprint.

Cite this