Abstract
A double-achromatic, double-focusing magnet system of very small size is described which will be used in the injection line for an undulator in a FEL experiment. Because of the double focusing no quadrupoles are needed between the dipole, which couples the electrons in the FEL cavity, and the undulator. An example will be worked out for an electron bunch of 25 MeV, 100 A which is focused on a spot of 1 mm diameter.
Original language | English |
---|---|
Pages (from-to) | 341-343 |
Number of pages | 3 |
Journal | Nuclear instruments & methods in physics research. Section A : Accelerators, spectrometers, detectors and associated equipment |
Volume | 318 |
Issue number | 1-3 |
DOIs | |
Publication status | Published - 1992 |
Event | 13th International Free-Electron Laser Conference, FEL 1991 - Santa Fe, United States Duration: 25 Aug 1991 → 30 Aug 1991 Conference number: 13 |