TY - JOUR
T1 - A Novel Plasma-Based Fluid for Particle Image Velocimetry (PIV)
T2 - In-Vitro Feasibility Study of Flow Diverter Effects in Aneurysm Model
AU - Clauser, Johanna
AU - Knieps, Marius S.
AU - Büsen, Martin
AU - Ding, Andreas
AU - Schmitz-Rode, Thomas
AU - Steinseifer, Ulrich
AU - Arens, Jutta
AU - Cattaneo, Giorgio
PY - 2018/6/1
Y1 - 2018/6/1
N2 - Particle image velocimetry (PIV) is a commonly used method for in vitro investigation of fluid dynamics in biomedical devices, such as flow diverters for intracranial aneurysm treatment. Since it is limited to transparent blood substituting fluids like water-glycerol mixture, the influence of coagulation and platelet aggregation is neglected. We aimed at the development and the application of a modified platelet rich plasma as a new PIV fluid with blood-like rheological and coagulation properties. In standardized intracranial aneurysm silicone models, the effect of this new PIV plasma on the fluid dynamics before and after flow diverter implantation was evaluated and compared with water-glycerol measurements. The flow diverting effect was strongly dependent on the used fluid, with considerably lower velocities achieved using PIV plasma, despite the same starting viscosity of both fluids. Moreover, triggering coagulation of PIV plasma allowed for intra-aneurysmal clot formation. We presented the first in vitro PIV investigation using a non-Newtonian, clottable PIV plasma, demonstrating a mismatch to a standard PIV fluid and allowing for thrombus formation.
AB - Particle image velocimetry (PIV) is a commonly used method for in vitro investigation of fluid dynamics in biomedical devices, such as flow diverters for intracranial aneurysm treatment. Since it is limited to transparent blood substituting fluids like water-glycerol mixture, the influence of coagulation and platelet aggregation is neglected. We aimed at the development and the application of a modified platelet rich plasma as a new PIV fluid with blood-like rheological and coagulation properties. In standardized intracranial aneurysm silicone models, the effect of this new PIV plasma on the fluid dynamics before and after flow diverter implantation was evaluated and compared with water-glycerol measurements. The flow diverting effect was strongly dependent on the used fluid, with considerably lower velocities achieved using PIV plasma, despite the same starting viscosity of both fluids. Moreover, triggering coagulation of PIV plasma allowed for intra-aneurysmal clot formation. We presented the first in vitro PIV investigation using a non-Newtonian, clottable PIV plasma, demonstrating a mismatch to a standard PIV fluid and allowing for thrombus formation.
KW - Blood rheology
KW - Flow diverter
KW - Intracranial aneurysm
KW - Particle image velocimetry (PIV)
KW - Platelet rich plasma (PRP)
UR - http://www.scopus.com/inward/record.url?scp=85042612699&partnerID=8YFLogxK
U2 - 10.1007/s10439-018-2002-1
DO - 10.1007/s10439-018-2002-1
M3 - Article
C2 - 29488139
AN - SCOPUS:85042612699
SN - 0090-6964
VL - 46
SP - 841
EP - 848
JO - Annals of biomedical engineering
JF - Annals of biomedical engineering
IS - 6
ER -