A Novel Tibiafemoral Kinematics Measurement System Based on Multi-Channel A-Mode Ultrasound System

Kenan Niu, Victor Sluiter, André Sprengers, Jasper Homminga, Nico Verdonschot

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

128 Downloads (Pure)

Abstract

Improving the accuracy of measuring 6 degree of freedom tibiofemoral kinematics is a crucial step in gait analysis. The skin-marker estimated kinematics is subject to soft tissue artefacts. Fluoroscopic systems have been reported to achieve high accurate kinematics, but induced irradiation and a limited field of view and its high cost hampers routine usage on large patient cohorts. The aim of this study is to assess the feasibility of measuring tibiofemoral kinematics using multi-channel A-mode ultrasound system in cadaver experiment and assess its achievable accuracy. A full cadaver was placed on the surgery table and legs were hanging in the air. Upper body was fixated and right leg was pulled by rope to generate a movement. To track the ground truth of the motion, two bone pins with optical markers were mounted to the femur and tibia separately. Six custom A-mode ultrasound holders containing 30 A-mode ultrasound transducers and 18 optical markers were mounted on six anatomical regions. Calculating the bone to each ultrasound transducer distance from ultrasound echo, and using the spatial information of the optical markers on the holders, 30 points were determined. The segmented bone models acquired from CT or MRI were registered to the corresponding points. Then the tibiofemoral kinematics were determined from the positions of registered femur and tibia per frame. This study has presented a multi-channel A-mode ultrasound system and proven its feasibility of reconstructing tibiofemoral kinematics in cadaver experiment. Although the reconstructed tibiofemoral kinematics is less accurate than fluoroscopic system, it outperforms skin-mounted markers system. Thus, this A- mode Ultrasound approach could provide a non-invasive and non-radiative method for measuring tibiofemoral kinematics, which may be used in clinic gait analysis or even computer-aided orthopedic surgery.
Original languageEnglish
Title of host publicationCAOS 2017
Subtitle of host publication17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
EditorsKlaus Radermacher, Ferdinando Rodriguez Y Baena
PublisherEasyChair
Pages166-170
Number of pages5
Volume1
DOIs
Publication statusPublished - 2017
Event17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, CAOS 2017 - Aachen, Germany
Duration: 14 Jun 201717 Jun 2017
Conference number: 17
http://www.caos2017.de/

Publication series

NameEPiC Series in Health Sciences
PublisherEasyChair

Conference

Conference17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, CAOS 2017
Abbreviated titleCAOS 2017
Country/TerritoryGermany
CityAachen
Period14/06/1717/06/17
Internet address

Fingerprint

Dive into the research topics of 'A Novel Tibiafemoral Kinematics Measurement System Based on Multi-Channel A-Mode Ultrasound System'. Together they form a unique fingerprint.

Cite this