A system for inducing concurrent tactile and nociceptive sensations at the same site using electrocutaneous stimulation

P. Steenbergen, Jan R. Buitenweg, J. Trojan, E.M. van der Heide, T. van den Heuvel, H. Flor, Petrus H. Veltink

    Research output: Contribution to journalArticleAcademicpeer-review

    16 Citations (Scopus)
    49 Downloads (Pure)

    Abstract

    Studies of the interaction between mechanoception and nociception would benefit from a method for stimulation of both modalities at the same location. For this purpose, we developed an electrical stimulation device. Using two different electrode geometries, discs and needles, the device is capable of inducing two distinct stimulus qualities, dull and sharp, at the same site on hairy skin. The perceived strength of the stimuli can be varied by applying stimulus pulse trains of different lengths. We assessed the perceived stimulus qualities and intensities of the two electrode geometries at two levels of physical stimulus intensity. In a first series of experiments, ten subjects participated in two experimental sessions. The subjects reported the perceived quality and intensity of four different stimulus classes on visual analogue scales (VASs). In a second series, we added a procedure in which subjects assigned descriptive labels to the stimuli. We assessed the reproducibility of the VAS scores by calculating intraclass correlation coefficients. The results showed that subjects perceived stimuli delivered through the disc electrodes as dull and those delivered through the needles as sharp. Increasing the pulse train length increased the perceived stimulus intensities without decreasing the difference in quality between the electrode types. The intraclass correlation coefficients for the VAS scores ranged from .75 to .95. The labels that were assigned for the two electrode geometries corresponded to the descriptors for nociception and touch reported by other researchers. We concluded that our device is capable of reliably inducing tactile and nociceptive sensations of controllable intensity at the same skin site.
    Original languageUndefined
    Pages (from-to)924-933
    Number of pages10
    JournalBehavior research methods
    Volume44
    Issue number4
    DOIs
    Publication statusPublished - Dec 2012

    Keywords

    • BSS-Electrical Neurostimulation
    • Multi modal stimulation
    • Quality of cutaneous perception
    • Nociception
    • Electric stimulation
    • IR-82367
    • Touch
    • Electrocutaneous stimulation
    • EWI-22616
    • METIS-293216
    • Reproducibility

    Cite this

    Steenbergen, P. ; Buitenweg, Jan R. ; Trojan, J. ; van der Heide, E.M. ; van den Heuvel, T. ; Flor, H. ; Veltink, Petrus H. / A system for inducing concurrent tactile and nociceptive sensations at the same site using electrocutaneous stimulation. In: Behavior research methods. 2012 ; Vol. 44, No. 4. pp. 924-933.
    @article{4589d55f34c34b8b8d73adfe8143bf51,
    title = "A system for inducing concurrent tactile and nociceptive sensations at the same site using electrocutaneous stimulation",
    abstract = "Studies of the interaction between mechanoception and nociception would benefit from a method for stimulation of both modalities at the same location. For this purpose, we developed an electrical stimulation device. Using two different electrode geometries, discs and needles, the device is capable of inducing two distinct stimulus qualities, dull and sharp, at the same site on hairy skin. The perceived strength of the stimuli can be varied by applying stimulus pulse trains of different lengths. We assessed the perceived stimulus qualities and intensities of the two electrode geometries at two levels of physical stimulus intensity. In a first series of experiments, ten subjects participated in two experimental sessions. The subjects reported the perceived quality and intensity of four different stimulus classes on visual analogue scales (VASs). In a second series, we added a procedure in which subjects assigned descriptive labels to the stimuli. We assessed the reproducibility of the VAS scores by calculating intraclass correlation coefficients. The results showed that subjects perceived stimuli delivered through the disc electrodes as dull and those delivered through the needles as sharp. Increasing the pulse train length increased the perceived stimulus intensities without decreasing the difference in quality between the electrode types. The intraclass correlation coefficients for the VAS scores ranged from .75 to .95. The labels that were assigned for the two electrode geometries corresponded to the descriptors for nociception and touch reported by other researchers. We concluded that our device is capable of reliably inducing tactile and nociceptive sensations of controllable intensity at the same skin site.",
    keywords = "BSS-Electrical Neurostimulation, Multi modal stimulation, Quality of cutaneous perception, Nociception, Electric stimulation, IR-82367, Touch, Electrocutaneous stimulation, EWI-22616, METIS-293216, Reproducibility",
    author = "P. Steenbergen and Buitenweg, {Jan R.} and J. Trojan and {van der Heide}, E.M. and {van den Heuvel}, T. and H. Flor and Veltink, {Petrus H.}",
    note = "Open Access",
    year = "2012",
    month = "12",
    doi = "10.3758/s13428-012-0216-y",
    language = "Undefined",
    volume = "44",
    pages = "924--933",
    journal = "Behavior research methods",
    issn = "1554-351X",
    publisher = "Springer",
    number = "4",

    }

    A system for inducing concurrent tactile and nociceptive sensations at the same site using electrocutaneous stimulation. / Steenbergen, P.; Buitenweg, Jan R.; Trojan, J.; van der Heide, E.M.; van den Heuvel, T.; Flor, H.; Veltink, Petrus H.

    In: Behavior research methods, Vol. 44, No. 4, 12.2012, p. 924-933.

    Research output: Contribution to journalArticleAcademicpeer-review

    TY - JOUR

    T1 - A system for inducing concurrent tactile and nociceptive sensations at the same site using electrocutaneous stimulation

    AU - Steenbergen, P.

    AU - Buitenweg, Jan R.

    AU - Trojan, J.

    AU - van der Heide, E.M.

    AU - van den Heuvel, T.

    AU - Flor, H.

    AU - Veltink, Petrus H.

    N1 - Open Access

    PY - 2012/12

    Y1 - 2012/12

    N2 - Studies of the interaction between mechanoception and nociception would benefit from a method for stimulation of both modalities at the same location. For this purpose, we developed an electrical stimulation device. Using two different electrode geometries, discs and needles, the device is capable of inducing two distinct stimulus qualities, dull and sharp, at the same site on hairy skin. The perceived strength of the stimuli can be varied by applying stimulus pulse trains of different lengths. We assessed the perceived stimulus qualities and intensities of the two electrode geometries at two levels of physical stimulus intensity. In a first series of experiments, ten subjects participated in two experimental sessions. The subjects reported the perceived quality and intensity of four different stimulus classes on visual analogue scales (VASs). In a second series, we added a procedure in which subjects assigned descriptive labels to the stimuli. We assessed the reproducibility of the VAS scores by calculating intraclass correlation coefficients. The results showed that subjects perceived stimuli delivered through the disc electrodes as dull and those delivered through the needles as sharp. Increasing the pulse train length increased the perceived stimulus intensities without decreasing the difference in quality between the electrode types. The intraclass correlation coefficients for the VAS scores ranged from .75 to .95. The labels that were assigned for the two electrode geometries corresponded to the descriptors for nociception and touch reported by other researchers. We concluded that our device is capable of reliably inducing tactile and nociceptive sensations of controllable intensity at the same skin site.

    AB - Studies of the interaction between mechanoception and nociception would benefit from a method for stimulation of both modalities at the same location. For this purpose, we developed an electrical stimulation device. Using two different electrode geometries, discs and needles, the device is capable of inducing two distinct stimulus qualities, dull and sharp, at the same site on hairy skin. The perceived strength of the stimuli can be varied by applying stimulus pulse trains of different lengths. We assessed the perceived stimulus qualities and intensities of the two electrode geometries at two levels of physical stimulus intensity. In a first series of experiments, ten subjects participated in two experimental sessions. The subjects reported the perceived quality and intensity of four different stimulus classes on visual analogue scales (VASs). In a second series, we added a procedure in which subjects assigned descriptive labels to the stimuli. We assessed the reproducibility of the VAS scores by calculating intraclass correlation coefficients. The results showed that subjects perceived stimuli delivered through the disc electrodes as dull and those delivered through the needles as sharp. Increasing the pulse train length increased the perceived stimulus intensities without decreasing the difference in quality between the electrode types. The intraclass correlation coefficients for the VAS scores ranged from .75 to .95. The labels that were assigned for the two electrode geometries corresponded to the descriptors for nociception and touch reported by other researchers. We concluded that our device is capable of reliably inducing tactile and nociceptive sensations of controllable intensity at the same skin site.

    KW - BSS-Electrical Neurostimulation

    KW - Multi modal stimulation

    KW - Quality of cutaneous perception

    KW - Nociception

    KW - Electric stimulation

    KW - IR-82367

    KW - Touch

    KW - Electrocutaneous stimulation

    KW - EWI-22616

    KW - METIS-293216

    KW - Reproducibility

    U2 - 10.3758/s13428-012-0216-y

    DO - 10.3758/s13428-012-0216-y

    M3 - Article

    VL - 44

    SP - 924

    EP - 933

    JO - Behavior research methods

    JF - Behavior research methods

    SN - 1554-351X

    IS - 4

    ER -