T1 - Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery
T2 - A goat model with four years follow-up
AU - Gareb, Barzi
AU - van Bakelen, Nico B.
AU - Driessen, Léon
AU - Buma, Pieter
AU - Kuipers, Jeroen
AU - Grijpma, Dirk W.
AU - Vissink, Arjan
AU - Bos, Ruud R.M.
AU - van Minnen, Baucke
N1 - Funding Information:
The authors would like to thank A. Güney and H.W.M. ten Hoopen for their assistance in the DSC and GPC analyses, respectively. The authors would also thank Mr. H. Croes for his assistance in using the scanning electron microscopy. B.N.G. Giepmans' contribution to the EDX analyses and interpretation is highly appreciated. Part of the work was performed in the UMCG Microscopy and Imaging Center (UMIC) and was supported by ZonMW grant 91111.006 .
Publisher Copyright:
© 2022 The Authors
PY - 2022/11
Y1 - 2022/11
N2 - Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70–78.5]LLA-co-[16–24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment.
AB - Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70–78.5]LLA-co-[16–24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment.
KW - Absorbable implants
KW - Biocompatible materials
KW - Fracture fixation
KW - Orthopaedic fixation devices
KW - Polymers
KW - Reconstructive surgical procedures
UR - http://www.scopus.com/inward/record.url?scp=85123008753&partnerID=8YFLogxK
U2 - 10.1016/j.bioactmat.2022.01.015
DO - 10.1016/j.bioactmat.2022.01.015
M3 - Article
AN - SCOPUS:85123008753
VL - 17
SP - 439
EP - 456
JO - Bioactive Materials
JF - Bioactive Materials
SN - 2452-199X
ER -