Abstract
Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor’s RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.
| Original language | English |
|---|---|
| Pages (from-to) | 1449-1459 |
| Number of pages | 11 |
| Journal | Journal of clinical monitoring and computing |
| Volume | 36 |
| Early online date | 8 Dec 2021 |
| DOIs | |
| Publication status | Published - Oct 2022 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- 22/1 OA procedure
Fingerprint
Dive into the research topics of 'Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting'. Together they form a unique fingerprint.Research output
- 15 Citations
- 1 PhD Thesis - Research external, graduation UT
-
Exploring the potential of virtual hospital care
Peters, G. M., 16 Apr 2024, Enschede: University of Twente. 281 p.Research output: Thesis › PhD Thesis - Research external, graduation UT
Open AccessFile409 Downloads (Pure)
Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver