Abstract
The stationary electric field and current distribution in a ring-shaped wire subject to both parallel and perpendicular applied magnetic fields are calculated. The time derivative of the parallel field is limited for the center of the wire to be unsaturated. The transient response of an infinitely long wire due to a parallel applied magnetic field BA shows that BA itself is limited for the center of the wire to be unsaturated. The measured V-I characteristic of a ring-shaped wire is linearly dependent on the frequency of the applied field but nonlinearly dependent on the amplitude. This means that the stationary analysis is not complete and transient effects must be considered
Original language | English |
---|---|
Pages (from-to) | 711-714 |
Number of pages | 4 |
Journal | IEEE transactions on magnetics |
Volume | 28javascript:void(0); |
Issue number | 1 |
DOIs | |
Publication status | Published - 1992 |
Event | 12th International Conference on Magnet Technology, MT-12 1991 - Leningrad (St. Petersburg), Russian Federation Duration: 24 Jun 1991 → 28 Jun 1991 Conference number: 12 |