Delta: a charge sensitive front-end amplifier with switched gain for low-noise, large dynamic range silicon detector readout

P. Aspell, D. Barney, P. Bloch, P. Jarron, B. Lofstedt, S. Reynaud, P. Tabbers

Research output: Contribution to journalArticleAcademic

6 Citations (Scopus)

Abstract

The design and results of a radiation hard switched gain charge amplifier optimised for a large dynamic range and large input capacitance are described. The peaking time is 25 ns, dynamic ranges are 0.1–50 minimum ionising particles (MIPs) (high gain) and 1–400 MIPs (low gain), signal to noise (S/N)>10 for Cin<56 pF and radiation tolerance to 10 Mrads(Si) and 4×1013 n cm−2.
Original languageUndefined
Pages (from-to)449-455
JournalNuclear instruments & methods in physics research. Section A : Accelerators, spectrometers, detectors and associated equipment
Volume461
Issue number1-3
DOIs
Publication statusPublished - 2001
Externally publishedYes

Keywords

  • Charge sensitive front-end amplifier
  • Large dynamic range
  • Low noise
  • IR-74565