Skip to main navigation Skip to search Skip to main content

Detecting early signs of patient deterioration at home using wearable sensors: A personalized anomaly detection approach

  • Sjoerd H. Garssen
  • , Sandra F. Oude Wesselink
  • , Sonja Babac
  • , Daphne L.J. Nabben
  • , Ashley J.R. de Bie Dekker
  • , Simon Nienhuijs
  • , Arthur R. Bouwman
  • , Wim F.J. Verhaegh
  • , C.J.M. Doggen*
  • , Bernard P. Veldkamp
  • , Maryam Amir Haeri
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

8 Downloads (Pure)

Abstract

In the rapidly emerging field of transferring healthcare from hospitals to patients’ homes, it is essential that signs of remote deterioration at home should be detected early to timely upscale care when needed. As patient deterioration is a rare event, datasets have insufficient event data for supervised machine learning. Personalized anomaly detection (AD) may be a good alternative. Therefore, this study aimed to obtain insight into the use of personalized AD models in detecting early signs of patient deterioration at home using wearable sensor data. To address this, Isolation Forest and Local Outlier Factor models were applied to detect signs of deterioration in terms of mortality or unplanned readmission in the 24 preceding hours in two datasets: one of heterogeneous patients, the other of postoperative patients. A pipeline was developed for continuously updating personalized AD models over time and applying them to detection windows twice per day. Results were compared with the Remote Early Warning Score. Isolation Forest (AUROC: 0.69) and Local Outlier Factor (AUROC: 0.67) models were able to find some early signs of deterioration in heterogeneous patients (n = 113). However, in postoperative patients (n = 193), Isolation Forest (AUROC: 0.41) and Local Outlier Factor (AUROC 0.44) performed badly. The Remote Early Warning Score was able to find some early signs of deterioration for both groups (AUROC: 0.63–0.76). Based on these findings, three requirements were formulated that should be fulfilled for a potentially successful application of personalized AD. First, the training set should be normal and representative of non-deteriorating patients. Second, signs of deterioration should exhibit abnormal characteristics. Third, non-deteriorating patients should not exhibit abnormal characteristics.
Original languageEnglish
Article number025058
Number of pages12
JournalBiomedical Physics & Engineering Express
Volume12
Issue number2
DOIs
Publication statusPublished - 2 Apr 2026

Keywords

  • UT-Hybrid-D

Fingerprint

Dive into the research topics of 'Detecting early signs of patient deterioration at home using wearable sensors: A personalized anomaly detection approach'. Together they form a unique fingerprint.

Cite this