Development and validation of a clinical CT system simulator

  • S. A.M. Tunissen
  • , L. J. Oostveen
  • , N. Moriakov
  • , J. Teuwen
  • , K. Michielsen
  • , E. J. Smit
  • , I. Sechopoulos

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

17 Downloads (Pure)

Abstract

Many advanced reconstruction and image processing methods are being developed with the aim of improving image quality in CT. Development and testing of these methods is aided by the ability to simulate realistic images, to both control the acquisition process and be able to use digital phantoms with known ground truth. Therefore, in this work, we present a method to simulate realistic scanner-specific sinograms from digital phantoms. For this, a series of measurements was conducted on a clinical CT system to characterize resolution loss, noise characteristics, and the exposure-to-detector output relationship. These measurements were used to develop a simulation pipeline, which involves raytracing of a digital phantom, taking into account the focal spot size and gantry rotation, followed by the use of Lambert's Law to determine the amount of energy arriving at each detector element. The spectrum for the specific tube voltage and current was modeled using previously published spectral models. The resulting sinogram was then corrupted, by applying the measured detector Modulation Transfer Function (MTF), and adding noise based on the Noise Power Spectrum (NPS) and mean-variance relationship. Simulator results were compared to those acquired with the CT system in our clinic, showing an average difference of 2.1% in the off-center MTF magnitude, 0.048 in normalized NPS magnitude and only 6 and 5 Hounsfield Units (HU) difference in the voxel values for respectively water and air. The developed simulator seems capable of generating realistic CT images, which can help researchers develop and test their algorithms.

Original languageEnglish
Title of host publicationMedical Imaging 2022
Subtitle of host publicationPhysics of Medical Imaging
EditorsWei Zhao, Lifeng Yu
PublisherSPIE
Volume12031
ISBN (Electronic)9781510649378
DOIs
Publication statusPublished - 2022
Externally publishedYes
EventMedical Imaging 2022: Physics of Medical Imaging - Virtual, Online
Duration: 21 Mar 202227 Mar 2022

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume12031
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2022: Physics of Medical Imaging
CityVirtual, Online
Period21/03/2227/03/22

Keywords

  • computer simulations
  • CT
  • system characterization