Skip to main navigation Skip to search Skip to main content

Does the Topology of Polymer Brushes Determine Their (Vapor-)Solvation?

Research output: Contribution to journalLetterAcademicpeer-review

45 Downloads (Pure)

Abstract

When the topology of polymer brushes is changed from linear to cyclic or looped, many of the brush properties will be improved. Yet, whether such a topology variation also affects the (vapor-)solvation and swelling of brushes has remained unclear. In fact, in a recent publication, Vagias and co-workers (Macromolecular Rapid Communications 2023, 44 (9), 2300035) reported an unequal swelling for linear and cyclic brushes and challenged theoreticians to develop a new Flory-Huggins theory that includes topology effects. In this letter, we address this challenge and employ molecular dynamics simulations to study the vapor swelling of linear, looped, and cyclic brushes. We find that the emergence of equal or unequal swelling for different topologies depends on the definition of the grafting density that is kept constant in the comparison. When suitably defined, the degree of swelling is independent of the topology, and the Flory-Huggins theory for brushes will describe brush swelling for all topologies in the present study.

Original languageEnglish
Pages (from-to)816-821
Number of pages6
JournalACS macro letters
Volume14
Issue number6
Early online date28 May 2025
DOIs
Publication statusPublished - 17 Jun 2025

Keywords

  • UT-Hybrid-D

Fingerprint

Dive into the research topics of 'Does the Topology of Polymer Brushes Determine Their (Vapor-)Solvation?'. Together they form a unique fingerprint.