We describe a test setup using two reverberation chambers with a common wall. In the common wall a device under test (DUT) can be mounted. One of the rooms is a conventional chamber with a stirrer. The other room is a Vibrating Intrinsic Reverberation Chamber (VIRC), where the walls are used to stir the fields, such as shown in Figure 1. The walls are moved by means of a simple motor with a crankshaft and elastic strings. Stirring the field by means of a mode stirrer is also possible
Original languageUndefined
Title of host publicationEuroEM2008
Place of PublicationLondon
PublisherSpringer
Pages-
Number of pages1
ISBN (Print)not assigned
Publication statusPublished - 21 Jul 2008

Publication series

Name
PublisherSpringer Verlag

Keywords

  • IR-62731
  • METIS-255888

Cite this

Schipper, J., Melenhorst, M., & Leferink, F. B. J. (2008). Dual reverberation chambers for high-dynamic range shielding effectiveness measurements. In EuroEM2008 (pp. -). London: Springer.
@inproceedings{98b67a96765445909dee0a0ce6a48933,
title = "Dual reverberation chambers for high-dynamic range shielding effectiveness measurements",
abstract = "We describe a test setup using two reverberation chambers with a common wall. In the common wall a device under test (DUT) can be mounted. One of the rooms is a conventional chamber with a stirrer. The other room is a Vibrating Intrinsic Reverberation Chamber (VIRC), where the walls are used to stir the fields, such as shown in Figure 1. The walls are moved by means of a simple motor with a crankshaft and elastic strings. Stirring the field by means of a mode stirrer is also possible",
keywords = "IR-62731, METIS-255888",
author = "J. Schipper and M. Melenhorst and Leferink, {Frank Bernardus Johannes}",
year = "2008",
month = "7",
day = "21",
language = "Undefined",
isbn = "not assigned",
publisher = "Springer",
pages = "--",
booktitle = "EuroEM2008",

}

Schipper, J, Melenhorst, M & Leferink, FBJ 2008, Dual reverberation chambers for high-dynamic range shielding effectiveness measurements. in EuroEM2008. Springer, London, pp. -.

Dual reverberation chambers for high-dynamic range shielding effectiveness measurements. / Schipper, J.; Melenhorst, M.; Leferink, Frank Bernardus Johannes.

EuroEM2008. London : Springer, 2008. p. -.

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademic

TY - GEN

T1 - Dual reverberation chambers for high-dynamic range shielding effectiveness measurements

AU - Schipper, J.

AU - Melenhorst, M.

AU - Leferink, Frank Bernardus Johannes

PY - 2008/7/21

Y1 - 2008/7/21

N2 - We describe a test setup using two reverberation chambers with a common wall. In the common wall a device under test (DUT) can be mounted. One of the rooms is a conventional chamber with a stirrer. The other room is a Vibrating Intrinsic Reverberation Chamber (VIRC), where the walls are used to stir the fields, such as shown in Figure 1. The walls are moved by means of a simple motor with a crankshaft and elastic strings. Stirring the field by means of a mode stirrer is also possible

AB - We describe a test setup using two reverberation chambers with a common wall. In the common wall a device under test (DUT) can be mounted. One of the rooms is a conventional chamber with a stirrer. The other room is a Vibrating Intrinsic Reverberation Chamber (VIRC), where the walls are used to stir the fields, such as shown in Figure 1. The walls are moved by means of a simple motor with a crankshaft and elastic strings. Stirring the field by means of a mode stirrer is also possible

KW - IR-62731

KW - METIS-255888

M3 - Conference contribution

SN - not assigned

SP - -

BT - EuroEM2008

PB - Springer

CY - London

ER -

Schipper J, Melenhorst M, Leferink FBJ. Dual reverberation chambers for high-dynamic range shielding effectiveness measurements. In EuroEM2008. London: Springer. 2008. p. -