Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning

S. Unnikrishnan, D. Kohlheyer, Stefan Schlautmann, A.J. Tudos, Richardus B.M. Schasfoort

    Research output: Contribution to conferencePoster

    Original languageUndefined
    Pages-
    Publication statusPublished - 31 Mar 2005
    Event7th Workshop on Sensor Technology 2005: Sense of Contact 2005 - Wageningen, Netherlands
    Duration: 31 Mar 20051 Apr 2005
    Conference number: 7

    Conference

    Conference7th Workshop on Sensor Technology 2005
    CountryNetherlands
    CityWageningen
    Period31/03/051/04/05

    Keywords

    • METIS-227841

    Cite this

    Unnikrishnan, S., Kohlheyer, D., Schlautmann, S., Tudos, A. J., & Schasfoort, R. B. M. (2005). Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning. -. Poster session presented at 7th Workshop on Sensor Technology 2005, Wageningen, Netherlands.
    Unnikrishnan, S. ; Kohlheyer, D. ; Schlautmann, Stefan ; Tudos, A.J. ; Schasfoort, Richardus B.M. / Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning. Poster session presented at 7th Workshop on Sensor Technology 2005, Wageningen, Netherlands.
    @conference{ff263a6431744b83bc0c0c0b8f4952f5,
    title = "Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning",
    keywords = "METIS-227841",
    author = "S. Unnikrishnan and D. Kohlheyer and Stefan Schlautmann and A.J. Tudos and Schasfoort, {Richardus B.M.}",
    year = "2005",
    month = "3",
    day = "31",
    language = "Undefined",
    pages = "--",
    note = "null ; Conference date: 31-03-2005 Through 01-04-2005",

    }

    Unnikrishnan, S, Kohlheyer, D, Schlautmann, S, Tudos, AJ & Schasfoort, RBM 2005, 'Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning' 7th Workshop on Sensor Technology 2005, Wageningen, Netherlands, 31/03/05 - 1/04/05, pp. -.

    Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning. / Unnikrishnan, S.; Kohlheyer, D.; Schlautmann, Stefan; Tudos, A.J.; Schasfoort, Richardus B.M.

    2005. - Poster session presented at 7th Workshop on Sensor Technology 2005, Wageningen, Netherlands.

    Research output: Contribution to conferencePoster

    TY - CONF

    T1 - Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning

    AU - Unnikrishnan, S.

    AU - Kohlheyer, D.

    AU - Schlautmann, Stefan

    AU - Tudos, A.J.

    AU - Schasfoort, Richardus B.M.

    PY - 2005/3/31

    Y1 - 2005/3/31

    KW - METIS-227841

    M3 - Poster

    SP - -

    ER -

    Unnikrishnan S, Kohlheyer D, Schlautmann S, Tudos AJ, Schasfoort RBM. Electroosmotically Controlled Perpendicular Address-Flow Chip for Biosensor Array Patterning. 2005. Poster session presented at 7th Workshop on Sensor Technology 2005, Wageningen, Netherlands.