Abstract
An experimental latent-thermal energy storage device (LTESD) with a flat miniature heat pipe array (FMHPA) as a core heat transfer element is designed. Multihole flat pipes are utilized as a heat supply and heat removal loop for the passage of heat transfer fluid (HTF). Experiments are performed at different HTF volume flow rates and inlet temperatures to investigate the performance of the thermal storage unit consisting of FMHPA and vertical fins and to observe the change in the temperature of phase-change materials, such as lauric acid. The effects of heating/cooling section length and thermal resistance are also examined. Results indicate that LTESD works stably and efficiently and the respective storing and releasing power are 1299 and 1120 W under standard operating conditions of 2 L/min at 70 °C and 2 L/min at 15 °C.
| Original language | English |
|---|---|
| Pages (from-to) | 929-941 |
| Number of pages | 13 |
| Journal | Energy |
| Volume | 138 |
| DOIs | |
| Publication status | Published - 2017 |
| Externally published | Yes |
Keywords
- Flat miniature heat pipe array
- Latent-thermal energy storage
- Laurel acid
- Multihole flat pipe
- n/a OA procedure
Fingerprint
Dive into the research topics of 'Experimental investigation on the heat transfer performance of a latent thermal energy storage device based on flat miniature heat pipe arrays'. Together they form a unique fingerprint.Cite this