TY - JOUR
T1 - Identification and Characterization of Plasma Cells in Normal Human Bone Marrow by High-Resolution Flow Cytometry
AU - Terstappen, Leonardus Wendelinus Mathias Marie
AU - Johnsen, Steen
AU - Segers-Nolten, Gezina M.J.
AU - Loken, Michael R.
PY - 1990
Y1 - 1990
N2 - The low frequency of plasma cells and the lack of specific cell surface markers has been a major obstacle for a detailed characterization of plasma cells in normal human bone marrow. Multiparameter flow cytometry enabled the identification of plasma cells in normal bone marrow aspirates. The plasma cells were located in a unique position in the correlation of forward light scattering, orthogonal light scattering, and immunofluorescent-labeled CD38. The identity of the sorted cell populations was confirmed by microscopic examination of Wright's stained slides and slides stained for cytoplasmic immunoglobulin using polyclonal antibodies reactive with light chains; ie, anti-kappa fluorescein isothiocyanate and anti lambda phycoerythrin (PE). The purity of the sorted plasma cells was greater than 97% (n = 4). The average frequency of plasma cells in normal bone marrow aspirates was low--0.25% of the nucleated cells (n = 7)--but surprisingly consistent between individuals (SD = .05; range 0.14% to 0.30%). A detailed analysis showed two distinct populations of plasma cells: (1) A population relatively smaller by forward light scattering expressed CD22, CD35, and sigE and was identified as early plasma cells (ie, lymphoplasmacytoid), and (2) a population larger by forward light scattering lacked these markers and was identified as mature plasma cells. The antigenic profile of the normal plasma cells was determined in two-color immunofluorescence studies. The expression of cell surface immunoglobulin G (IgG), IgA, IgE, IgD, IgM, and the cell surface antigens CD10, CD11b, CD13, CD11c, CD14, CD15, CD16, CD19, CD22, CD20, CD33, CD35, CD45, and HLA-DR was determined on the plasma cells. A significant heterogeneity in cell surface antigen expression was observed within the plasma cell population. Unexpectedly, myeloid- specific cell surface antigens such as CD33 and CD13 and the early B- cell antigen identified by CD10 were expressed on a proportion of plasma cells. These observations imply that the association of myeloid and early B-cell markers described in multiple myeloma may not be associated with the neoplasia but is a normal phenomenon.
AB - The low frequency of plasma cells and the lack of specific cell surface markers has been a major obstacle for a detailed characterization of plasma cells in normal human bone marrow. Multiparameter flow cytometry enabled the identification of plasma cells in normal bone marrow aspirates. The plasma cells were located in a unique position in the correlation of forward light scattering, orthogonal light scattering, and immunofluorescent-labeled CD38. The identity of the sorted cell populations was confirmed by microscopic examination of Wright's stained slides and slides stained for cytoplasmic immunoglobulin using polyclonal antibodies reactive with light chains; ie, anti-kappa fluorescein isothiocyanate and anti lambda phycoerythrin (PE). The purity of the sorted plasma cells was greater than 97% (n = 4). The average frequency of plasma cells in normal bone marrow aspirates was low--0.25% of the nucleated cells (n = 7)--but surprisingly consistent between individuals (SD = .05; range 0.14% to 0.30%). A detailed analysis showed two distinct populations of plasma cells: (1) A population relatively smaller by forward light scattering expressed CD22, CD35, and sigE and was identified as early plasma cells (ie, lymphoplasmacytoid), and (2) a population larger by forward light scattering lacked these markers and was identified as mature plasma cells. The antigenic profile of the normal plasma cells was determined in two-color immunofluorescence studies. The expression of cell surface immunoglobulin G (IgG), IgA, IgE, IgD, IgM, and the cell surface antigens CD10, CD11b, CD13, CD11c, CD14, CD15, CD16, CD19, CD22, CD20, CD33, CD35, CD45, and HLA-DR was determined on the plasma cells. A significant heterogeneity in cell surface antigen expression was observed within the plasma cell population. Unexpectedly, myeloid- specific cell surface antigens such as CD33 and CD13 and the early B- cell antigen identified by CD10 were expressed on a proportion of plasma cells. These observations imply that the association of myeloid and early B-cell markers described in multiple myeloma may not be associated with the neoplasia but is a normal phenomenon.
KW - METIS-129410
KW - IR-60744
M3 - Article
SN - 0006-4971
VL - 76
SP - 1739
EP - 1747
JO - Blood
JF - Blood
IS - 9
ER -