Identification of left ventricular model parameters

H.B.K. Boom, Hessel Wijkstra

    Research output: Contribution to conferencePaper

    2 Citations (Scopus)
    144 Downloads (Pure)

    Abstract

    Simulations with a model of left ventricular pressure generation consisting of time-varying elastance, resistance, series-elastance, and deactivation were fitted to pressure curves measured in the isolated rabbit ventricle. For constant ejection flows, a fit with a RMS error of 2.78 mmHg was obtained provided that deactivation was actually incorporated in the model. Deactivation was assumed to depend linearly on end ejection pressure. Resistance was found to be independent of volume
    Original languageUndefined
    Pages126-127
    DOIs
    Publication statusPublished - 1989
    Event11th Annual International Conference of the IEEE Engineering in Engineering in Medicine and Biology Society, EMBC 1989 - Seattle, United States
    Duration: 9 Nov 198912 Nov 1989
    Conference number: 11

    Conference

    Conference11th Annual International Conference of the IEEE Engineering in Engineering in Medicine and Biology Society, EMBC 1989
    Abbreviated titleEMBC
    Country/TerritoryUnited States
    CitySeattle
    Period9/11/8912/11/89

    Keywords

    • IR-56100

    Cite this