In-situ measurement of chloride ion concentration in concrete

Yawar Abbas

    Research output: ThesisPhD Thesis - Research UT, graduation UT

    250 Downloads (Pure)

    Abstract

    Chloride ions are one of the major contributors to degradation of reinforcement-concrete. The presence of these ions initiate pitting corrosion in the reinforcement steel and ultimately results in the failure of the construction. Thus, the chloride ion concentration inside concrete is a crucial parameter to predict the service life of a structure. Potentiometric measurement is the state-of-the-art technique to measure chloride ion concentration in concrete. Despite promising results, this technique is limited to lab-scale measurements because drift in the reference potential causes flawed data. This work is focused on omitting or improving the reference electrode to obtain a reliable and drift free data for long-term measurements. First, a dynamic electrochemical technique, to remove the need for a reference electrode, is treated. An alternative to the potentiometric measurement (zero current technique) is chronopotentiometry, which is a dynamic electrochemical approach. It is proposed as a reference free technique. The response does not depend on the absolute reference potential and any metal wire can be used as a pseudo-reference electrode. Second, an alternative for a long-term reference electrode, i.e. Kynol based activated carbon (AC) pseudo-reference electrode, is treated. The that activated carbon has a huge double layer capacitance (in the order of tens of Farad per gram) and has a better material stability in concrete environment. The high double layer capacitance countervails any small changes in adsorption/desorption reaction (non-faradaic) which would cause a change in its electrode potential. Along with the chloride ion concentration, the corrosion status of steel is an additional aspect for determining the structural deterioration. A rigorous corrosion sensor which indicates the active or passive state of corrosion is presented. The time constant of a decaying potential, after a current pulse is interrupted, gives the status of corrosion of reinforcement steel. Overall this work demonstrates some solutions to the challenges in the measurement of chloride ion in concrete, especially when using a long-term embedded reference electrode. This will help in building a new type of chloride sensor system for concrete based on dynamic electrochemical measurement with embedded corrosion sensors and a better pseudo-reference electrode
    Original languageEnglish
    Awarding Institution
    • University of Twente
    Supervisors/Advisors
    • van den Berg, Albert , Supervisor
    • Olthuis, Wouter , Co-Supervisor
    Thesis sponsors
    Award date20 Nov 2015
    Place of PublicationEnschede
    Publisher
    Print ISBNs978-90-365-3991-3
    DOIs
    Publication statusPublished - 20 Nov 2015

    Fingerprint

    Concretes
    Electrodes
    Ions
    Corrosion
    Activated carbon
    Steel
    Sensors
    Reinforcement
    Capacitance
    Concrete reinforcements
    Pitting
    Service life
    Deterioration
    Desorption
    Wire
    Adsorption
    Degradation
    Metals

    Keywords

    • METIS-313041
    • EWI-26539
    • IR-98025

    Cite this

    Abbas, Yawar. / In-situ measurement of chloride ion concentration in concrete. Enschede : University of Twente, 2015. 166 p.
    @phdthesis{d76c7d3f9dee48508136dbec446199ee,
    title = "In-situ measurement of chloride ion concentration in concrete",
    abstract = "Chloride ions are one of the major contributors to degradation of reinforcement-concrete. The presence of these ions initiate pitting corrosion in the reinforcement steel and ultimately results in the failure of the construction. Thus, the chloride ion concentration inside concrete is a crucial parameter to predict the service life of a structure. Potentiometric measurement is the state-of-the-art technique to measure chloride ion concentration in concrete. Despite promising results, this technique is limited to lab-scale measurements because drift in the reference potential causes flawed data. This work is focused on omitting or improving the reference electrode to obtain a reliable and drift free data for long-term measurements. First, a dynamic electrochemical technique, to remove the need for a reference electrode, is treated. An alternative to the potentiometric measurement (zero current technique) is chronopotentiometry, which is a dynamic electrochemical approach. It is proposed as a reference free technique. The response does not depend on the absolute reference potential and any metal wire can be used as a pseudo-reference electrode. Second, an alternative for a long-term reference electrode, i.e. Kynol based activated carbon (AC) pseudo-reference electrode, is treated. The that activated carbon has a huge double layer capacitance (in the order of tens of Farad per gram) and has a better material stability in concrete environment. The high double layer capacitance countervails any small changes in adsorption/desorption reaction (non-faradaic) which would cause a change in its electrode potential. Along with the chloride ion concentration, the corrosion status of steel is an additional aspect for determining the structural deterioration. A rigorous corrosion sensor which indicates the active or passive state of corrosion is presented. The time constant of a decaying potential, after a current pulse is interrupted, gives the status of corrosion of reinforcement steel. Overall this work demonstrates some solutions to the challenges in the measurement of chloride ion in concrete, especially when using a long-term embedded reference electrode. This will help in building a new type of chloride sensor system for concrete based on dynamic electrochemical measurement with embedded corrosion sensors and a better pseudo-reference electrode",
    keywords = "METIS-313041, EWI-26539, IR-98025",
    author = "Yawar Abbas",
    year = "2015",
    month = "11",
    day = "20",
    doi = "10.3990/1.9789036539913",
    language = "English",
    isbn = "978-90-365-3991-3",
    publisher = "University of Twente",
    address = "Netherlands",
    school = "University of Twente",

    }

    In-situ measurement of chloride ion concentration in concrete. / Abbas, Yawar.

    Enschede : University of Twente, 2015. 166 p.

    Research output: ThesisPhD Thesis - Research UT, graduation UT

    TY - THES

    T1 - In-situ measurement of chloride ion concentration in concrete

    AU - Abbas, Yawar

    PY - 2015/11/20

    Y1 - 2015/11/20

    N2 - Chloride ions are one of the major contributors to degradation of reinforcement-concrete. The presence of these ions initiate pitting corrosion in the reinforcement steel and ultimately results in the failure of the construction. Thus, the chloride ion concentration inside concrete is a crucial parameter to predict the service life of a structure. Potentiometric measurement is the state-of-the-art technique to measure chloride ion concentration in concrete. Despite promising results, this technique is limited to lab-scale measurements because drift in the reference potential causes flawed data. This work is focused on omitting or improving the reference electrode to obtain a reliable and drift free data for long-term measurements. First, a dynamic electrochemical technique, to remove the need for a reference electrode, is treated. An alternative to the potentiometric measurement (zero current technique) is chronopotentiometry, which is a dynamic electrochemical approach. It is proposed as a reference free technique. The response does not depend on the absolute reference potential and any metal wire can be used as a pseudo-reference electrode. Second, an alternative for a long-term reference electrode, i.e. Kynol based activated carbon (AC) pseudo-reference electrode, is treated. The that activated carbon has a huge double layer capacitance (in the order of tens of Farad per gram) and has a better material stability in concrete environment. The high double layer capacitance countervails any small changes in adsorption/desorption reaction (non-faradaic) which would cause a change in its electrode potential. Along with the chloride ion concentration, the corrosion status of steel is an additional aspect for determining the structural deterioration. A rigorous corrosion sensor which indicates the active or passive state of corrosion is presented. The time constant of a decaying potential, after a current pulse is interrupted, gives the status of corrosion of reinforcement steel. Overall this work demonstrates some solutions to the challenges in the measurement of chloride ion in concrete, especially when using a long-term embedded reference electrode. This will help in building a new type of chloride sensor system for concrete based on dynamic electrochemical measurement with embedded corrosion sensors and a better pseudo-reference electrode

    AB - Chloride ions are one of the major contributors to degradation of reinforcement-concrete. The presence of these ions initiate pitting corrosion in the reinforcement steel and ultimately results in the failure of the construction. Thus, the chloride ion concentration inside concrete is a crucial parameter to predict the service life of a structure. Potentiometric measurement is the state-of-the-art technique to measure chloride ion concentration in concrete. Despite promising results, this technique is limited to lab-scale measurements because drift in the reference potential causes flawed data. This work is focused on omitting or improving the reference electrode to obtain a reliable and drift free data for long-term measurements. First, a dynamic electrochemical technique, to remove the need for a reference electrode, is treated. An alternative to the potentiometric measurement (zero current technique) is chronopotentiometry, which is a dynamic electrochemical approach. It is proposed as a reference free technique. The response does not depend on the absolute reference potential and any metal wire can be used as a pseudo-reference electrode. Second, an alternative for a long-term reference electrode, i.e. Kynol based activated carbon (AC) pseudo-reference electrode, is treated. The that activated carbon has a huge double layer capacitance (in the order of tens of Farad per gram) and has a better material stability in concrete environment. The high double layer capacitance countervails any small changes in adsorption/desorption reaction (non-faradaic) which would cause a change in its electrode potential. Along with the chloride ion concentration, the corrosion status of steel is an additional aspect for determining the structural deterioration. A rigorous corrosion sensor which indicates the active or passive state of corrosion is presented. The time constant of a decaying potential, after a current pulse is interrupted, gives the status of corrosion of reinforcement steel. Overall this work demonstrates some solutions to the challenges in the measurement of chloride ion in concrete, especially when using a long-term embedded reference electrode. This will help in building a new type of chloride sensor system for concrete based on dynamic electrochemical measurement with embedded corrosion sensors and a better pseudo-reference electrode

    KW - METIS-313041

    KW - EWI-26539

    KW - IR-98025

    U2 - 10.3990/1.9789036539913

    DO - 10.3990/1.9789036539913

    M3 - PhD Thesis - Research UT, graduation UT

    SN - 978-90-365-3991-3

    PB - University of Twente

    CY - Enschede

    ER -