TY - JOUR
T1 - In vivo testing of crosslinked polyethers. I
T2 - Tissue reactions and biodegradation
AU - Pol, B.J.M.
AU - van der Does, L.
AU - Bantjes, A.
AU - van Wachem, P.B.
AU - van Luyn, M.J.A.
PY - 1996
Y1 - 1996
N2 - The in vivo biocompatibility and biodegradation of crosslinked (co)polyethers with and without tertiary hydrogen atoms in the main chain and differing in hydrophilicity were studied by means of subcutaneous implantation in rats. After 4 days, 1 month, and 3 months postimplantation, the tissue reactions and interactions were evaluated by light microscopy (LM) and transmission electron microscopy (TEM). Poly(tetrahydrofuran) (poly(THF)), poly(propylene oxide) (poly(POx)), and poly(tetrahydrofuran-co-oxetane) (poly-(THF-co-OX)) were tested as relatively hydrophobic polyethers, and poly(ethylene oxide) (PEO) and a poly(THF)/PEO blend were used as more hydrophilic materials. In general, all polyethers showed good biocompatibility with respect to tissue reactions and interactions, with low neutrophil and macrophage infiltration, a quiet giant cell reaction, and formation of a thin fibrous capsule. For the relatively hydrophobic polyethers studied, the biostability increased in the order poly(POx) < poly(THF-co-OX) < poly(THF), probably indicating that the absence of tertiary hydrogen atoms has a positive effect on the biostability. Concerning the more hydrophilic materials, crosslinked PEO showed the highest rate of degradation, probably due to the mechanical weakness of the hydrogel in combination with the highest presence of giant cells as a result of the high porosity. A frayed surface morphology was observed after implantation of the crosslinked poly(THF)/PEO blend, which might be due to preferential degradation of PEO domains.
AB - The in vivo biocompatibility and biodegradation of crosslinked (co)polyethers with and without tertiary hydrogen atoms in the main chain and differing in hydrophilicity were studied by means of subcutaneous implantation in rats. After 4 days, 1 month, and 3 months postimplantation, the tissue reactions and interactions were evaluated by light microscopy (LM) and transmission electron microscopy (TEM). Poly(tetrahydrofuran) (poly(THF)), poly(propylene oxide) (poly(POx)), and poly(tetrahydrofuran-co-oxetane) (poly-(THF-co-OX)) were tested as relatively hydrophobic polyethers, and poly(ethylene oxide) (PEO) and a poly(THF)/PEO blend were used as more hydrophilic materials. In general, all polyethers showed good biocompatibility with respect to tissue reactions and interactions, with low neutrophil and macrophage infiltration, a quiet giant cell reaction, and formation of a thin fibrous capsule. For the relatively hydrophobic polyethers studied, the biostability increased in the order poly(POx) < poly(THF-co-OX) < poly(THF), probably indicating that the absence of tertiary hydrogen atoms has a positive effect on the biostability. Concerning the more hydrophilic materials, crosslinked PEO showed the highest rate of degradation, probably due to the mechanical weakness of the hydrogel in combination with the highest presence of giant cells as a result of the high porosity. A frayed surface morphology was observed after implantation of the crosslinked poly(THF)/PEO blend, which might be due to preferential degradation of PEO domains.
KW - METIS-105389
KW - IR-71266
U2 - 10.1002/(SICI)1097-4636(199611)32:3<307::AID-JBM3>3.0.CO;2-W
DO - 10.1002/(SICI)1097-4636(199611)32:3<307::AID-JBM3>3.0.CO;2-W
M3 - Article
SN - 0021-9304
VL - 32
SP - 307
EP - 320
JO - Journal of biomedical materials research
JF - Journal of biomedical materials research
IS - 32
ER -