Level-Set Based Artery-Vein Separation in Blood Pool Agent CE-MR Angiograms

C.M. van Bemmel, Lieuwe Jan Spreeuwers, M.A. Viergever, W.J. Niessen

    Research output: Contribution to journalArticleAcademicpeer-review

    71 Citations (Scopus)
    232 Downloads (Pure)

    Abstract

    Blood pool agents (BPAs) for contrast-enhanced (CE) magnetic-resonance angiography (MRA) allow prolonged imaging times for higher contrast and resolution. Imaging is performed during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous venous and arterial enhancement in this steady state hampers interpretation. In order to improve visualization of the arteries and veins from steady-state BPA data, a semiautomated method for artery-vein separation is presented. In this method, the central arterial axis and central venous axis are used as initializations for two surfaces that simultaneously evolve in order to capture the arterial and venous parts of the vasculature using the level-set framework. Since arteries and veins can be in close proximity of each other, leakage from the evolving arterial (venous) surface into the venous (arterial) part of the vasculature is inevitable. In these situations, voxels are labeled arterial or venous based on the arrival time of the respective surface. The evolution is steered by external forces related to feature images derived from the image data and by internal forces related to the geometry of the level sets. In this paper, the robustness and accuracy of three external forces (based on image intensity, image gradient, and vessel-enhancement filtering) and combinations of them are investigated and tested on seven patient datasets. To this end, results with the level-set-based segmentation are compared to the reference-standard manually obtained segmentations. Best results are achieved by applying a combination of intensity- and gradient-based forces and a smoothness constraint based on the curvature of the surface. By applying this combination to the seven datasets, it is shown that, with minimal user interaction, artery-vein separation for improved arterial and venous visualization in BPA CE-MRA can be achieved.
    Original languageUndefined
    Article number10.1109/TMI.2003.817756
    Pages (from-to)1224-1234
    Number of pages11
    JournalIEEE transactions on medical imaging
    Volume22
    Issue number10
    DOIs
    Publication statusPublished - 2003

    Keywords

    • IR-65060
    • EWI-13881

    Cite this