Low-field MRI: An MR physics perspective

José P. Marques, Frank F.J. Simonis, Andrew G. Webb

Research output: Contribution to journalReview articleAcademicpeer-review

5 Citations (Scopus)
33 Downloads (Pure)

Abstract

Historically, clinical MRI started with main magnetic field strengths in the ∼0.05–0.35T range. In the past 40 years there have been considerable developments in MRI hardware, with one of the primary ones being the trend to higher magnetic fields. While resulting in large improvements in data quality and diagnostic value, such developments have meant that conventional systems at 1.5 and 3T remain relatively expensive pieces of medical imaging equipment, and are out of the financial reach for much of the world. In this review we describe the current state-of-the-art of low-field systems (defined as 0.25–1T), both with respect to its low cost, low foot-print, and subject accessibility. Furthermore, we discuss how low field could potentially benefit from many of the developments that have occurred in higher-field MRI. In the first section, the signal-to-noise ratio (SNR) dependence on the static magnetic field and its impact on the achievable contrast, resolution, and acquisition times are discussed from a theoretical perspective. In the second section, developments in hardware (eg, magnet, gradient, and RF coils) used both in experimental low-field scanners and also those that are currently in the market are reviewed. In the final section the potential roles of new acquisition readouts, motion tracking, and image reconstruction strategies, currently being developed primarily at higher fields, are presented. Level of Evidence: 5. Technical Efficacy Stage: 1. J. Magn. Reson. Imaging 2019.

Original languageEnglish
Pages (from-to)1528-1542
Number of pages15
JournalJournal of magnetic resonance imaging
Volume49
Issue number6
Early online date13 Jan 2019
DOIs
Publication statusPublished - 1 Jun 2019

Fingerprint

Physics
Magnetic Fields
Computer-Assisted Image Processing
Magnets
Signal-To-Noise Ratio
Diagnostic Imaging
Foot
Costs and Cost Analysis
Equipment and Supplies

Keywords

  • UT-Hybrid-D
  • MRI
  • state-of-the-art
  • low-field systems

Cite this

Marques, José P. ; Simonis, Frank F.J. ; Webb, Andrew G. / Low-field MRI : An MR physics perspective. In: Journal of magnetic resonance imaging. 2019 ; Vol. 49, No. 6. pp. 1528-1542.
@article{ac433b8d07f7410e8ef3e01b1c4a8719,
title = "Low-field MRI: An MR physics perspective",
abstract = "Historically, clinical MRI started with main magnetic field strengths in the ∼0.05–0.35T range. In the past 40 years there have been considerable developments in MRI hardware, with one of the primary ones being the trend to higher magnetic fields. While resulting in large improvements in data quality and diagnostic value, such developments have meant that conventional systems at 1.5 and 3T remain relatively expensive pieces of medical imaging equipment, and are out of the financial reach for much of the world. In this review we describe the current state-of-the-art of low-field systems (defined as 0.25–1T), both with respect to its low cost, low foot-print, and subject accessibility. Furthermore, we discuss how low field could potentially benefit from many of the developments that have occurred in higher-field MRI. In the first section, the signal-to-noise ratio (SNR) dependence on the static magnetic field and its impact on the achievable contrast, resolution, and acquisition times are discussed from a theoretical perspective. In the second section, developments in hardware (eg, magnet, gradient, and RF coils) used both in experimental low-field scanners and also those that are currently in the market are reviewed. In the final section the potential roles of new acquisition readouts, motion tracking, and image reconstruction strategies, currently being developed primarily at higher fields, are presented. Level of Evidence: 5. Technical Efficacy Stage: 1. J. Magn. Reson. Imaging 2019.",
keywords = "UT-Hybrid-D, MRI, state-of-the-art, low-field systems",
author = "Marques, {Jos{\'e} P.} and Simonis, {Frank F.J.} and Webb, {Andrew G.}",
note = "Wiley deal",
year = "2019",
month = "6",
day = "1",
doi = "10.1002/jmri.26637",
language = "English",
volume = "49",
pages = "1528--1542",
journal = "Journal of magnetic resonance imaging",
issn = "1053-1807",
publisher = "Wiley",
number = "6",

}

Low-field MRI : An MR physics perspective. / Marques, José P.; Simonis, Frank F.J.; Webb, Andrew G.

In: Journal of magnetic resonance imaging, Vol. 49, No. 6, 01.06.2019, p. 1528-1542.

Research output: Contribution to journalReview articleAcademicpeer-review

TY - JOUR

T1 - Low-field MRI

T2 - An MR physics perspective

AU - Marques, José P.

AU - Simonis, Frank F.J.

AU - Webb, Andrew G.

N1 - Wiley deal

PY - 2019/6/1

Y1 - 2019/6/1

N2 - Historically, clinical MRI started with main magnetic field strengths in the ∼0.05–0.35T range. In the past 40 years there have been considerable developments in MRI hardware, with one of the primary ones being the trend to higher magnetic fields. While resulting in large improvements in data quality and diagnostic value, such developments have meant that conventional systems at 1.5 and 3T remain relatively expensive pieces of medical imaging equipment, and are out of the financial reach for much of the world. In this review we describe the current state-of-the-art of low-field systems (defined as 0.25–1T), both with respect to its low cost, low foot-print, and subject accessibility. Furthermore, we discuss how low field could potentially benefit from many of the developments that have occurred in higher-field MRI. In the first section, the signal-to-noise ratio (SNR) dependence on the static magnetic field and its impact on the achievable contrast, resolution, and acquisition times are discussed from a theoretical perspective. In the second section, developments in hardware (eg, magnet, gradient, and RF coils) used both in experimental low-field scanners and also those that are currently in the market are reviewed. In the final section the potential roles of new acquisition readouts, motion tracking, and image reconstruction strategies, currently being developed primarily at higher fields, are presented. Level of Evidence: 5. Technical Efficacy Stage: 1. J. Magn. Reson. Imaging 2019.

AB - Historically, clinical MRI started with main magnetic field strengths in the ∼0.05–0.35T range. In the past 40 years there have been considerable developments in MRI hardware, with one of the primary ones being the trend to higher magnetic fields. While resulting in large improvements in data quality and diagnostic value, such developments have meant that conventional systems at 1.5 and 3T remain relatively expensive pieces of medical imaging equipment, and are out of the financial reach for much of the world. In this review we describe the current state-of-the-art of low-field systems (defined as 0.25–1T), both with respect to its low cost, low foot-print, and subject accessibility. Furthermore, we discuss how low field could potentially benefit from many of the developments that have occurred in higher-field MRI. In the first section, the signal-to-noise ratio (SNR) dependence on the static magnetic field and its impact on the achievable contrast, resolution, and acquisition times are discussed from a theoretical perspective. In the second section, developments in hardware (eg, magnet, gradient, and RF coils) used both in experimental low-field scanners and also those that are currently in the market are reviewed. In the final section the potential roles of new acquisition readouts, motion tracking, and image reconstruction strategies, currently being developed primarily at higher fields, are presented. Level of Evidence: 5. Technical Efficacy Stage: 1. J. Magn. Reson. Imaging 2019.

KW - UT-Hybrid-D

KW - MRI

KW - state-of-the-art

KW - low-field systems

UR - http://www.scopus.com/inward/record.url?scp=85060111594&partnerID=8YFLogxK

U2 - 10.1002/jmri.26637

DO - 10.1002/jmri.26637

M3 - Review article

VL - 49

SP - 1528

EP - 1542

JO - Journal of magnetic resonance imaging

JF - Journal of magnetic resonance imaging

SN - 1053-1807

IS - 6

ER -