TY - JOUR
T1 - Lysozyme-responsive polymer systems for detection of infection
AU - Schiffer, Doris
AU - Verient, Vanessa
AU - Luschnig, Daniel
AU - Blokhuis-Arkes, Miriam H.E.
AU - van der Palen, J.V.D.
AU - Gamerith, Clemens
AU - Burnet, Michael
AU - Sigl, Eva
AU - Heinzle, Andrea
AU - Guebitz, Georg M.
PY - 2015/5/1
Y1 - 2015/5/1
N2 - There is a strong need for new point-of-care systems for the detection of wound infection. Overseen infections in chronic wounds induce severe complications, such as delayed healing and high risks for the patients, while time-consuming common gold and silver standard methods for infection assessment cannot be implemented in home care units. This study demonstrates for the first time the between correlation of lysozyme activity and silver-standard microbiological evaluation of wounds. Significantly higher (eightfold increase; p < 0.001) lysozyme activity in infected wounds was in accordance with increasing bacterial burden of infected wound fluids. Moreover, a two-layer membrane-based test system was developed providing visible results on infection in a short time (30 min) while avoiding any intermediate steps such as centrifugation. In the first layer of the system, a size exclusion membrane (1.2-8 μm cut-off) retained labeled peptidoglycane while allowing only smaller fragments resulting from lysozyme hydrolysis to pass through. These fragments were then captured in a second layer, an anion-exchanging diethylaminoethyl cellulose membrane, resulting in clearly visible color changes. Colorimetric measurements demonstrated significant differences (p < 0.001) and sixfold higher delta E values between infected and noninfected wound fluids. This system allows a quick and straightforward determination of the status of a wound. The colorimetric readout indicates the increased lysozyme activity in infected wound fluid.
AB - There is a strong need for new point-of-care systems for the detection of wound infection. Overseen infections in chronic wounds induce severe complications, such as delayed healing and high risks for the patients, while time-consuming common gold and silver standard methods for infection assessment cannot be implemented in home care units. This study demonstrates for the first time the between correlation of lysozyme activity and silver-standard microbiological evaluation of wounds. Significantly higher (eightfold increase; p < 0.001) lysozyme activity in infected wounds was in accordance with increasing bacterial burden of infected wound fluids. Moreover, a two-layer membrane-based test system was developed providing visible results on infection in a short time (30 min) while avoiding any intermediate steps such as centrifugation. In the first layer of the system, a size exclusion membrane (1.2-8 μm cut-off) retained labeled peptidoglycane while allowing only smaller fragments resulting from lysozyme hydrolysis to pass through. These fragments were then captured in a second layer, an anion-exchanging diethylaminoethyl cellulose membrane, resulting in clearly visible color changes. Colorimetric measurements demonstrated significant differences (p < 0.001) and sixfold higher delta E values between infected and noninfected wound fluids. This system allows a quick and straightforward determination of the status of a wound. The colorimetric readout indicates the increased lysozyme activity in infected wound fluid.
KW - Biomedical application
KW - Diagnosis
KW - Environment-responsive biopolymers
KW - Lysozyme
KW - Wound infection
KW - n/a OA procedure
UR - http://www.scopus.com/inward/record.url?scp=84929507244&partnerID=8YFLogxK
U2 - 10.1002/elsc.201400145
DO - 10.1002/elsc.201400145
M3 - Article
AN - SCOPUS:84929507244
SN - 1618-0240
VL - 15
SP - 368
EP - 375
JO - Engineering in Life Sciences
JF - Engineering in Life Sciences
IS - 4
ER -