Monte Carlo simulation of photon-counting breast CT system: from implementation to image quality evaluation

  • Alessandra Tomal*
  • , Koen Michielsen
  • , Juan J. Pautasso
  • , Ioannis Sechopoulos
  • *Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Academic › peer-review

Abstract

Photon-counting detectors (PCD) are an emerging technology that has the potential to improve the image quality and material characterization capabilities in breast CT (bCT) compared to energy-integrating detectors (EID). This work focuses on implementing a Monte Carlo (MC) model to simulate PCD, using a previously validated Geant4-based MC code. MC simulations of bCT acquisitions, using both PC and EI detection technologies, were performed to investigate image quality improvement. To evaluate PCD simulation performance, a 50 keV beam was simulated with an energy threshold of 20 keV and four energy bins. The detection efficiency was 88%, with 24% of the counts corresponding to the incorrect energy channel due to partial energy deposition and charge-sharing effects. For image quality evaluation, projection images for bCT were simulated using anthropomorphic breast phantoms with an added iodinated spherical lesion and a W/Cu (0.257 mm) at 65 kV x-ray spectrum. 225 projections were simulated, and CT images were reconstructed using IMPACT method. Image quality was evaluated using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Comparing the simulated projections, the SNR and CNR increased, respectively, by up to 88/95% and 31/35% for single/multichannel PCD vs. EID. For the reconstructed images, the improvements were up to 27%/9%. It was observed a better accuracy and precision of linear attenuation coefficient estimation for PCD (PCD: 4.4% and 3.0%, and EID: 6.7% and 3.3%, on average, respectively). Overall, the PCD detector provides improved image quality and more accurate tissue characterization compared to the EID detector for bCT.

Original languageEnglish
Title of host publicationMedical Imaging 2025
Subtitle of host publicationPhysics of Medical Imaging
EditorsJohn M. Sabol, Ke Li, Shiva Abbaszadeh
PublisherSPIE
ISBN (Electronic)9781510685888
DOIs
Publication statusPublished - 2025
Externally publishedYes
EventSPIE Medical Imaging 2025 - San Diego, United States
Duration: 16 Feb 2025 → 20 Feb 2025

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume13405
ISSN (Print)1605-7422

Conference

ConferenceSPIE Medical Imaging 2025
Country/TerritoryUnited States
CitySan Diego
Period16/02/25 → 20/02/25

Keywords

  • n/a OA procedure
  • Monte Carlo simulation
  • photon-counting detector
  • dedicated breast CT