Skip to main navigation Skip to search Skip to main content

Motion-resolved parametric imaging derived from short dynamic [18F]FDG PET/CT scans

  • Alessia Artesani*
  • , Joyce van Sluis
  • , Laura Providência
  • , Johannes H. van Snick
  • , Riemer H.J.A. Slart
  • , Walter Noordzij
  • , Charalampos Tsoumpas
  • *Corresponding author for this work

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

Purpose: This study aims to assess the added value of utilizing short-dynamic whole-body PET/CT scans and implementing motion correction before quantifying metabolic rate, offering more insights into physiological processes. While this approach may not be commonly adopted, addressing motion effects is crucial due to their demonstrated potential to cause significant errors in parametric imaging. Methods: A 15-minute dynamic FDG PET acquisition protocol was utilized for four lymphoma patients undergoing therapy evaluation. Parametric imaging was obtained using a population-based input function (PBIF) derived from twelve patients with full 65-minute dynamic FDG PET acquisition. AI-based registration methods were employed to correct misalignments between both PET and ACCT and PET-to-PET. Tumour characteristics were assessed using both parametric images and standardized uptake values (SUV). Results: The motion correction process significantly reduced mismatches between images without significantly altering voxel intensity values, except for SUVmax. Following the alignment of the attenuation correction map with the PET frame, an increase in SUVmax in FDG-avid lymph nodes was observed, indicating its susceptibility to spatial misalignments. In contrast, Patlak Ki parameter was highly sensitive to misalignment across PET frames, that notably altered the Patlak slope. Upon completion of the motion correction process, the parametric representation revealed heterogeneous behaviour among lymph nodes compared to SUV images. Notably, reduced volume of elevated metabolic rate was determined in the mediastinal lymph nodes in contrast with an SUV of 5 g/ml, indicating potential perfusion or inflammation. Conclusions: Motion resolved short-dynamic PET can enhance the utility and reliability of parametric imaging, an aspect often overlooked in commercial software.

Original languageEnglish
Article number105010
JournalPhysica medica
Volume135
DOIs
Publication statusPublished - Jul 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • n/a OA procedure
  • Motion correction
  • Parametric imaging
  • Short dynamic scan
  • Total body PET
  • Lymphoma therapy

Fingerprint

Dive into the research topics of 'Motion-resolved parametric imaging derived from short dynamic [18F]FDG PET/CT scans'. Together they form a unique fingerprint.

Cite this