Moving On: Measuring Movement Remotely after Stroke

Research output: ThesisPhD Thesis - Research UT, graduation UT

633 Downloads (Pure)

Abstract

Most persons with stroke suffer from motor impairment, which restricts mobility on one side, and affects their independence in daily life activities. Measuring recovery is needed to develop individualized therapies. However, commonly used clinical outcomes suffer from low resolution and subjectivity. Therefore, objective biomechanical metrics should be identified to measure movement quality. However, non-portable laboratory setups are required in order to measure these metrics accurately. Alternatively, minimal wearable systems can be developed to simplify measurements performed at clinic or home to monitor recovery. Thus, the goal of the thesis was ‘To identify metrics that reflect movement quality of upper and lower extremities after stroke and develop wearable minimal systems for tracking the proposed metrics’.

Section Upper Extremity
First, we systematically reviewed literature (Chapter II) to identify metrics used to measure reaching recovery longitudinally post-stroke. Although several metrics were found, it was not clear how they differentiated recovery from compensation strategies. Future studies must address this gap in order to optimize stroke therapy. Next, we assessed a ‘valid’ measure for smoothness of upper paretic limb reaching (Chapter III), as this was commonly used to measure movement quality. After a systematic review and simulation analyses, we found that reaching smoothness is best measured using spectral arc length. The studies in this section offer us a better understanding of movement recovery in the upper extremity post-stroke.

Section Lower Extremity
Although metrics that reflect gait recovery are yet to be identified, in this section we focused on developing minimal solutions to measure gait quality. First, we showed the feasibility of 1D pressure insoles as a lightweight alternative for measuring 3D Ground Reaction Forces (GRF) (Chapter IV). In the following chapters, we developed a minimal system; the Portable Gait Lab (PGL) using only three Inertial Measurement Units (IMUs) (one per foot and one on the pelvis). We explored the Centroidal Moment Pivot (CMP) point (Chapter V) as a biomechanical constraint that can help with the reduction in sensors. Then, we showed the feasibility of the PGL to track 3D GRF (Chapters VI-VII) and relative foot and CoM kinematics (Chapter VIII-IX) during variable overground walking by healthy participants. Finally, we performed a limited validation study in persons with chronic stroke (Chapter X).

This thesis offers knowledge and tools which can help clinicians and researchers understand movement quality and thereby develop individualized therapies post-stroke.
Original languageEnglish
QualificationDoctor of Philosophy
Awarding Institution
  • University of Twente
Supervisors/Advisors
  • Veltink, Peter H., Supervisor
  • Buurke, Jaap H., Supervisor
  • van Beijnum, Bert-Jan F., Co-Supervisor
Award date7 Jul 2021
Place of PublicationEnschede
Publisher
Print ISBNs978-90-365-5170-0
Electronic ISBNs978-90-365-5170-0
DOIs
Publication statusPublished - 2021

Keywords

  • Stroke recovery
  • Movement quality
  • Reaching
  • Gait quality
  • Balance
  • Inertial Measurement Units
  • Wearable sensing

Fingerprint

Dive into the research topics of 'Moving On: Measuring Movement Remotely after Stroke'. Together they form a unique fingerprint.

Cite this