Outcome of percutaneous coronary intervention using ultrathin-strut biodegradable polymer sirolimus-eluting versus thin-strut durable polymer zotarolimus-eluting stents in patients with comorbid peripheral arterial disease: a post-hoc analysis from two randomized trials

Tineke H. Pinxterhuis, Eline H. Ploumen, Paolo Zocca, Carine J.M. Doggen, Carl E. Schotborgh, Rutger L. Anthonio, Ariel Roguin, Peter W. Danse, Edouard Benit, Adel Aminian, K. Gert van Houwelingen, Gerard C.M. Linssen, Robert H. Geelkerken, Clemens von Birgelen*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

31 Downloads (Pure)

Abstract

Background: In patients with peripheral arterial disease (PADs), who underwent percutaneous coronary intervention (PCI), little is known about the potential impact of using different new-generation drug-eluting stents (DES) on outcome. In PCI all-comers, the results of most between-stent comparisons—stratified by strut thickness—suggested some advantage of coronary stents with ultrathin-struts. The current post-hoc analysis aimed to assess outcomes of PCI with ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) vs. thin-strut durable polymer zotarolimus-eluting stents (DP-ZES) in patients with PADs. Methods: We pooled 3-year patient-level data from two large-scale randomized all-comer trials to compare Orsiro ultrathin-strut BP-SES vs. Resolute-type thin-strut DP-ZES in trial participants with concomitant PADs. BIO-RESORT (December 2012 to August 2015) and BIONYX (October 2015 to December 2016) included all-comer patients who were aged 18 years or older, capable of providing informed consent, and required a PCI. The trials had web-based randomization, with block sizes of 4 and 8, performed in a 1:1:1 or 1:1 fashion. Assessors, research staff, and patients were blinded to the type of stent used. We assessed the composite main clinical endpoint target vessel failure [TVF: cardiac death, target vessel related myocardial infarction (MI), or clinically indicated target vessel revascularization (TVR)], its components, and stent thrombosis. Results: Of 4,830 trial participants, 360 had PADs: 177 (49.2%) were treated with BP-SES and 183 (50.8%) with DP-ZES. Baseline characteristics were similar. For BP-SES, the 3-year TVF rate was 11.0% and for DP-ZES 17.9% [hazard ratio (HR): 0.59, 95% CI: 0.33–1.04; P=0.07]. For BP-SES, the TVR rate was lower than for DP-ZES (4.1% vs. 11.0%; HR: 0.36, 95% CI: 0.15–0.86; P=0.016), but this did not translate into between-group differences in cardiac death or MI. In small vessels (<2.75 mm), the TVR rate was also lower in BP-SES (5.6% vs. 13.9%; HR: 0.32, 95% CI: 0.11–0.91; P=0.024). Definite-or-probable stent thrombosis rates were 1.2% and 2.3% (P=0.43). Conclusions: In PCI patients with PADs, the 3-year TVF incidence was numerically lower in the ultrathin-strut BP-SES vs. the thin-strut DP-ZES group. Furthermore, TVR risk was significantly lower in ultrathin-strut BP-SES, mainly driven by a lower TVR rate in small vessels.

Original languageEnglish
Pages (from-to)673-685
Number of pages13
JournalCardiovascular diagnosis and therapy
Volume13
Issue number4
DOIs
Publication statusPublished - 31 Aug 2023

Keywords

  • Coronary artery disease
  • drug-eluting stent
  • percutaneous coronary intervention (PCI)
  • peripheral arterial disease (PADs)
  • randomized trial

Fingerprint

Dive into the research topics of 'Outcome of percutaneous coronary intervention using ultrathin-strut biodegradable polymer sirolimus-eluting versus thin-strut durable polymer zotarolimus-eluting stents in patients with comorbid peripheral arterial disease: a post-hoc analysis from two randomized trials'. Together they form a unique fingerprint.

Cite this