TY - JOUR
T1 - Performance of first insert coil with REBCO CICC sub-size cable exceeding 6 kA at 21 T magnetic field
AU - Zhou, Chao
AU - Jin, Huan
AU - Fang, Zhen
AU - Xiao, Guanyu
AU - Ma, Hongjun
AU - Liu, Fang
AU - Liu, Huajun
AU - Ma, Tao
AU - Tan, Yunfei
AU - Chen, Wenge
AU - Wu, Zuojiafeng
AU - Kanazawa, Shintetsu
AU - Nijhuis, Arend
AU - Devred, Arnaud
AU - Li, Jiangang
AU - Qin, Jinggang
N1 - Funding Information:
This work was in part supported by the Strategic Priority Research Program of the Chinese Academy of Sciences under Grant No. XDB25000000, the Comprehensive Research Facility for the Fusion Technology Program of China under Contract No. 2018-000052-73-01-001228, the National Nature Science Foundation of China (No. 52077212) and the Youth Innovation Promotion Association of CAS (Grant No.2021444).
Publisher Copyright:
© 2022 IOP Publishing Ltd.
PY - 2022/11
Y1 - 2022/11
N2 - The Institute of Plasma Physics at the Chinese Academy of Sciences is developing the REBCO cable in conduit conductor (CICC) technology for applications in next-generation nuclear fusion devices. The aim is to develop a CICC comprised of six REBCO sub-cables to satisfy the requirements of operation with a current of around 40 kA and a peak field of up to 20 T. To qualify the performance of the sub-size REBCO cable to be used in the CICC, two 25-turn insert solenoids have been designed, manufactured and tested at a current exceeding 6 kA subjected in a background field supplied by a water-cooled resistive magnet. The insert solenoid, wound from a 11.5 m long REBCO CORC® cable, was designed to investigate its current carrying capacity under high field and electromagnetic (EM) load at 4.2 K. Tests were performed under a background magnetic field up to 18.5 T, resulting in a peak magnetic field on the innermost layer turns of around 21.1 T at an operating current of 6.3 kA. The effects of operation with cyclic EM loads were tested by repeated current ramps to around 95% of the critical current. Moreover, the V-I characteristics were measured at 77 K and the self-field, to check the effects from warm-up and cool-down (WUCD) cycles between room temperature and 77 K with liquid nitrogen. The results show no obvious degradation after dozens of high-current test cycles in background fields ranging from 10 T to 18.5 T. The insert solenoid demonstrates the stable operation of the REBCO sub-size cable for CICC with EM loads of about 90 kN m-1 and WUCD cycles between room temperature and 77 K. These promising results indicate the potential of this technology for further applicationsin particular, for full-size CICC for high-performance fusion magnets.
AB - The Institute of Plasma Physics at the Chinese Academy of Sciences is developing the REBCO cable in conduit conductor (CICC) technology for applications in next-generation nuclear fusion devices. The aim is to develop a CICC comprised of six REBCO sub-cables to satisfy the requirements of operation with a current of around 40 kA and a peak field of up to 20 T. To qualify the performance of the sub-size REBCO cable to be used in the CICC, two 25-turn insert solenoids have been designed, manufactured and tested at a current exceeding 6 kA subjected in a background field supplied by a water-cooled resistive magnet. The insert solenoid, wound from a 11.5 m long REBCO CORC® cable, was designed to investigate its current carrying capacity under high field and electromagnetic (EM) load at 4.2 K. Tests were performed under a background magnetic field up to 18.5 T, resulting in a peak magnetic field on the innermost layer turns of around 21.1 T at an operating current of 6.3 kA. The effects of operation with cyclic EM loads were tested by repeated current ramps to around 95% of the critical current. Moreover, the V-I characteristics were measured at 77 K and the self-field, to check the effects from warm-up and cool-down (WUCD) cycles between room temperature and 77 K with liquid nitrogen. The results show no obvious degradation after dozens of high-current test cycles in background fields ranging from 10 T to 18.5 T. The insert solenoid demonstrates the stable operation of the REBCO sub-size cable for CICC with EM loads of about 90 kN m-1 and WUCD cycles between room temperature and 77 K. These promising results indicate the potential of this technology for further applicationsin particular, for full-size CICC for high-performance fusion magnets.
KW - electromagnetic load
KW - high field
KW - REBCO insert solenoid
KW - warm-up-cool-down treatment
KW - 22/4 OA procedure
UR - http://www.scopus.com/inward/record.url?scp=85139679568&partnerID=8YFLogxK
U2 - 10.1088/1361-6668/ac8cbc
DO - 10.1088/1361-6668/ac8cbc
M3 - Article
AN - SCOPUS:85139679568
SN - 0953-2048
VL - 35
JO - Superconductor science and technology
JF - Superconductor science and technology
IS - 11
M1 - 114003
ER -