Skip to main navigation Skip to search Skip to main content

Performance of first insert coil with REBCO CICC sub-size cable exceeding 6 kA at 21 T magnetic field

  • Chao Zhou
  • , Huan Jin*
  • , Zhen Fang
  • , Guanyu Xiao
  • , Hongjun Ma
  • , Fang Liu
  • , Huajun Liu
  • , Tao Ma
  • , Yunfei Tan
  • , Wenge Chen
  • , Zuojiafeng Wu
  • , Shintetsu Kanazawa
  • , Arend Nijhuis
  • , Arnaud Devred
  • , Jiangang Li
  • , Jinggang Qin*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › Academic › peer-review

190 Downloads (Pure)

Abstract

The Institute of Plasma Physics at the Chinese Academy of Sciences is developing the REBCO cable in conduit conductor (CICC) technology for applications in next-generation nuclear fusion devices. The aim is to develop a CICC comprised of six REBCO sub-cables to satisfy the requirements of operation with a current of around 40 kA and a peak field of up to 20 T. To qualify the performance of the sub-size REBCO cable to be used in the CICC, two 25-turn insert solenoids have been designed, manufactured and tested at a current exceeding 6 kA subjected in a background field supplied by a water-cooled resistive magnet. The insert solenoid, wound from a 11.5 m long REBCO CORC® cable, was designed to investigate its current carrying capacity under high field and electromagnetic (EM) load at 4.2 K. Tests were performed under a background magnetic field up to 18.5 T, resulting in a peak magnetic field on the innermost layer turns of around 21.1 T at an operating current of 6.3 kA. The effects of operation with cyclic EM loads were tested by repeated current ramps to around 95% of the critical current. Moreover, the V-I characteristics were measured at 77 K and the self-field, to check the effects from warm-up and cool-down (WUCD) cycles between room temperature and 77 K with liquid nitrogen. The results show no obvious degradation after dozens of high-current test cycles in background fields ranging from 10 T to 18.5 T. The insert solenoid demonstrates the stable operation of the REBCO sub-size cable for CICC with EM loads of about 90 kN m-1 and WUCD cycles between room temperature and 77 K. These promising results indicate the potential of this technology for further applicationsin particular, for full-size CICC for high-performance fusion magnets.

Original languageEnglish
Article number114003
JournalSuperconductor science and technology
Volume35
Issue number11
Early online date29 Sept 2022
DOIs
Publication statusPublished - Nov 2022

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • electromagnetic load
  • high field
  • REBCO insert solenoid
  • warm-up-cool-down treatment
  • 22/4 OA procedure

Fingerprint

Dive into the research topics of 'Performance of first insert coil with REBCO CICC sub-size cable exceeding 6 kA at 21 T magnetic field'. Together they form a unique fingerprint.

Cite this