T1 - Potential of Medical Management to Mitigate Suction Events in Ventricular Assist Device Patients
AU - Rocchi, Maria
AU - Fresiello, Libera
AU - Jacobs, Steven
AU - Dauwe, Dieter
AU - Droogne, Walter
AU - Meyns, Bart
N1 - Funding Information:
The study was supported by an FWO project 1SD0321N and by an internal KU Leuven C1 project C14/18/080.
Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/6/1
Y1 - 2022/6/1
N2 - Ventricular suction is a common adverse event in ventricular assist device (VAD) patients and can be due to multiple underlying causes. The aim of this study is to analyze the potential of different therapeutic interventions to mitigate suction events induced by different pathophysiological conditions. To do so, a suction module was embedded in a cardiovascular hybrid (hydraulic-computational) simulator reproducing the entire cardiovascular system. An HVAD system (Medtronic) was connected between a compliant ventricular apex and a simulated aorta. Starting from a patient profile with severe dilated cardiomyopathy, four different pathophysiological conditions leading to suction were simulated: hypovolemia (blood volume: -900 ml), right ventricular failure (contractility -70%), hypotension (systemic vascular resistance: 8.3 Wood Units), and tachycardia (heart rate:185 bpm). Different therapeutic interventions such as volume infusion, ventricular contractility increase, vasoconstriction, heart rate increase, and pump speed reduction were simulated. Their effects were compared in terms of general hemodynamics and suction mitigation. Each intervention elicited a different effect on the hemodynamics for every pathophysiological condition. Pump speed reduction mitigated suction but did not ameliorate the hemodynamics. Administering volume and inducing a systemic vasoconstriction were the most efficient interventions in both improving the hemodynamics and mitigating suction. When simulating volume infusion, the cardiac powers increased, respectively, by 38%, 25%, 42%, and 43% in the case of hypovolemia, right ventricular failure, hypotension, and tachycardia. Finally, a management algorithm is proposed to identify a therapeutic intervention suited for the underlying physiologic condition causing suction.
AB - Ventricular suction is a common adverse event in ventricular assist device (VAD) patients and can be due to multiple underlying causes. The aim of this study is to analyze the potential of different therapeutic interventions to mitigate suction events induced by different pathophysiological conditions. To do so, a suction module was embedded in a cardiovascular hybrid (hydraulic-computational) simulator reproducing the entire cardiovascular system. An HVAD system (Medtronic) was connected between a compliant ventricular apex and a simulated aorta. Starting from a patient profile with severe dilated cardiomyopathy, four different pathophysiological conditions leading to suction were simulated: hypovolemia (blood volume: -900 ml), right ventricular failure (contractility -70%), hypotension (systemic vascular resistance: 8.3 Wood Units), and tachycardia (heart rate:185 bpm). Different therapeutic interventions such as volume infusion, ventricular contractility increase, vasoconstriction, heart rate increase, and pump speed reduction were simulated. Their effects were compared in terms of general hemodynamics and suction mitigation. Each intervention elicited a different effect on the hemodynamics for every pathophysiological condition. Pump speed reduction mitigated suction but did not ameliorate the hemodynamics. Administering volume and inducing a systemic vasoconstriction were the most efficient interventions in both improving the hemodynamics and mitigating suction. When simulating volume infusion, the cardiac powers increased, respectively, by 38%, 25%, 42%, and 43% in the case of hypovolemia, right ventricular failure, hypotension, and tachycardia. Finally, a management algorithm is proposed to identify a therapeutic intervention suited for the underlying physiologic condition causing suction.
KW - cardiovascular simulators
KW - lumped parameter models
KW - medical management
KW - suction
KW - ventricular assist devices
KW - n/a OA procedure
UR - http://www.scopus.com/inward/record.url?scp=85131268271&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000001573
DO - 10.1097/MAT.0000000000001573
M3 - Article
C2 - 34524148
AN - SCOPUS:85131268271
SN - 1058-2916
VL - 68
SP - 814
EP - 821
JO - ASAIO Journal
JF - ASAIO Journal
IS - 6
ER -