TY - JOUR
T1 - Prophylactic Surgical Left Atrial Appendage Closure in Bioprosthetic Aortic Valve Replacement
T2 - Short‐Term Outcomes of Randomized Controlled LAA–CLOSURE Trial
AU - Kiviniemi, Tuomas
AU - Halfwerk, Frank
AU - Bustamante-Munguira, Juan
AU - Zindovic, Igor
AU - Malmberg, Markus
AU - Olsson, Christian
AU - Perrotta, Sossio
AU - van Schaagen, Frank
AU - Suwalski, Piotr
AU - Hartikainen, Juha
AU - Hanke, Thorsten
AU - Copa, Guillermo Reyes
AU - Speekenbrink, Ron G.H.
AU - Bustamante, Elena
AU - Erixon, Clara
AU - Gunn, Jarmo
AU - Bjurbom, Markus
AU - Jeppsson, Anders
AU - Oei, Frans
AU - Wietsma, Nicobert E.
AU - Dahlberg, Sofia
AU - Lip, Gregory
AU - Lehto, Joonas
AU - Vasankari, Tuija
AU - Airaksinen, Juhani
AU - van Putte, Bart
AU - LAA-CLOSURE Investigators
N1 - © 2026 The Author(s). Published on behalf of the American Heart Association, Inc., by Wiley.
PY - 2026/9/1
Y1 - 2026/9/1
N2 - BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF.METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73 years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30 days.RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at ≈7 days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7 days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30 days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively.CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding.
AB - BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF.METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73 years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30 days.RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at ≈7 days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7 days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30 days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively.CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding.
KW - atrial fibrillation
KW - clip closure
KW - left atrial appendage
KW - stroke
KW - systemic embolism
UR - https://www.scopus.com/pages/publications/105049015326
U2 - 10.1161/JAHA.125.046654
DO - 10.1161/JAHA.125.046654
M3 - Article
SN - 2047-9980
VL - 15
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 17
M1 - e046654
ER -