Quantification of minimal needed cable terminations

    Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

    5 Citations (Scopus)

    Abstract

    Cable terminations act as a boundary for common mode currents for all screened cable entries. Those common mode currents are attenuated by breaking up and shorting the common mode current paths, for instance between the inside and outside of the equipment cabinet. In this paper, cable terminations have been modelled as magnetically coupled loops with a bonding resistance and this model has been validated. The minimal needed bonding resistance has been established based on measurements and calculations.
    Original languageUndefined
    Title of host publication2015 Asia-pacific International Symposium on Electromagnetic Compatibility (APEMC)
    Place of PublicationUSA
    PublisherIEEE Electromagnetic Compatibility Society
    Pages470-473
    Number of pages4
    ISBN (Print)978-1-4799-6668-4
    DOIs
    Publication statusPublished - 28 May 2015
    Event2015 Asia-pacific International Symposium on Electromagnetic Compatibility, APEMC 2015 - Taipei, Taiwan, Province of China
    Duration: 25 May 201529 May 2015