Self Field Measurements by Hall Sensors on the SeCRETS Long Sample CICCs in SULTAN

Y. Ilyin, Arend Nijhuis, Herman H.J. ten Kate, P. Bruzzone

Research output: Contribution to journalArticleAcademicpeer-review

6 Citations (Scopus)
178 Downloads (Pure)

Abstract

The aim of this work is to determine the existence and degree of the current unbalance of two types of cable-in-conduit conductors (CICC) of the SeCRETS long sample experiment, and its influence on the conductors' performance. The self-field measurements are performed by using six sets of annular Hall sensors, each containing six sensors, and two linear arrays with ten sensors. The change of the self-field is associated with the redistribution of the transport current between the strands inside the conductor during and after a ramp of current, due to changes of the applied magnetic field or temperature of the conductor. During the DC, AC losses and stability tests, the signals from the Hall sensors were recorded. In DC tests, a clear change of the self-field pattern is observed in the high field region when either current or temperature approached their critical (I/sub cs/ and T/sub cs/) values. No change in the self-field pattern is observed in the experiments with pulsed fields. The method requires improvements for a reasonable quantitative assessment of the current unbalance in the conductor.
Original languageUndefined
Pages (from-to)1667-1674
Number of pages5
JournalIEEE transactions on applied superconductivity
Volume12
Issue number1
DOIs
Publication statusPublished - 2002

Keywords

  • METIS-206757
  • IR-43493

Cite this