Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy

Carsten Cleff, Petra Groß, Sven Dobner, Carsten Fallnich, Herman L. Offerhaus, Jennifer L. Herek, Kai Kruse, Willem P. Beeker, Chris J. Lee, Klaus-Jochen Boller

Research output: Contribution to conferenceAbstract

33 Downloads (Pure)

Abstract

Suppression of CARS signal generation is demonstrated by equalization of the ground and Raman states via a control state in a theoretical investigation. Using donut-shaped control light fields for population transfer results in sub-diffraction-limited spatial resolution CARS microscopy.
Original languageEnglish
DOIs
Publication statusPublished - 17 Jun 2012
EventAccess Networks and In-house Communications, ANIC 2012 - Colorado Springs, United States
Duration: 20 Jun 201220 Jun 2012

Conference

ConferenceAccess Networks and In-house Communications, ANIC 2012
Abbreviated titleANIC
CountryUnited States
CityColorado Springs
Period20/06/1220/06/12

Fingerprint

stimulated emission
pumping
spatial resolution
microscopy
diffraction
retarding
ground state

Cite this

Cleff, C., Groß, P., Dobner, S., Fallnich, C., Offerhaus, H. L., Herek, J. L., ... Boller, K-J. (2012). Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy. Abstract from Access Networks and In-house Communications, ANIC 2012, Colorado Springs, United States. https://doi.org/10.1364/ANIC.2012.JM5A.14
Cleff, Carsten ; Groß, Petra ; Dobner, Sven ; Fallnich, Carsten ; Offerhaus, Herman L. ; Herek, Jennifer L. ; Kruse, Kai ; Beeker, Willem P. ; Lee, Chris J. ; Boller, Klaus-Jochen. / Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy. Abstract from Access Networks and In-house Communications, ANIC 2012, Colorado Springs, United States.
@conference{164165ab3cbe4ce8af3232a604ebd869,
title = "Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy",
abstract = "Suppression of CARS signal generation is demonstrated by equalization of the ground and Raman states via a control state in a theoretical investigation. Using donut-shaped control light fields for population transfer results in sub-diffraction-limited spatial resolution CARS microscopy.",
author = "Carsten Cleff and Petra Gro{\ss} and Sven Dobner and Carsten Fallnich and Offerhaus, {Herman L.} and Herek, {Jennifer L.} and Kai Kruse and Beeker, {Willem P.} and Lee, {Chris J.} and Klaus-Jochen Boller",
year = "2012",
month = "6",
day = "17",
doi = "10.1364/ANIC.2012.JM5A.14",
language = "English",
note = "Access Networks and In-house Communications, ANIC 2012, ANIC ; Conference date: 20-06-2012 Through 20-06-2012",

}

Cleff, C, Groß, P, Dobner, S, Fallnich, C, Offerhaus, HL, Herek, JL, Kruse, K, Beeker, WP, Lee, CJ & Boller, K-J 2012, 'Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy' Access Networks and In-house Communications, ANIC 2012, Colorado Springs, United States, 20/06/12 - 20/06/12, . https://doi.org/10.1364/ANIC.2012.JM5A.14

Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy. / Cleff, Carsten; Groß, Petra; Dobner, Sven; Fallnich, Carsten; Offerhaus, Herman L.; Herek, Jennifer L.; Kruse, Kai; Beeker, Willem P.; Lee, Chris J.; Boller, Klaus-Jochen.

2012. Abstract from Access Networks and In-house Communications, ANIC 2012, Colorado Springs, United States.

Research output: Contribution to conferenceAbstract

TY - CONF

T1 - Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy

AU - Cleff, Carsten

AU - Groß, Petra

AU - Dobner, Sven

AU - Fallnich, Carsten

AU - Offerhaus, Herman L.

AU - Herek, Jennifer L.

AU - Kruse, Kai

AU - Beeker, Willem P.

AU - Lee, Chris J.

AU - Boller, Klaus-Jochen

PY - 2012/6/17

Y1 - 2012/6/17

N2 - Suppression of CARS signal generation is demonstrated by equalization of the ground and Raman states via a control state in a theoretical investigation. Using donut-shaped control light fields for population transfer results in sub-diffraction-limited spatial resolution CARS microscopy.

AB - Suppression of CARS signal generation is demonstrated by equalization of the ground and Raman states via a control state in a theoretical investigation. Using donut-shaped control light fields for population transfer results in sub-diffraction-limited spatial resolution CARS microscopy.

U2 - 10.1364/ANIC.2012.JM5A.14

DO - 10.1364/ANIC.2012.JM5A.14

M3 - Abstract

ER -

Cleff C, Groß P, Dobner S, Fallnich C, Offerhaus HL, Herek JL et al. Stimulated Emission Pumping Enabling Sub-Diffraction-Limited Spatial Resolution in CARS Microscopy. 2012. Abstract from Access Networks and In-house Communications, ANIC 2012, Colorado Springs, United States. https://doi.org/10.1364/ANIC.2012.JM5A.14