TY - JOUR
T1 - The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Technique for Aorto-Iliac Occlusive Disease
AU - Abdelbaqy, Omar Ma
AU - Holewijn, Suzanne
AU - Zeebregts, Clark J.
AU - Reijnen, Michel M.P.J.
PY - 2022/5/19
Y1 - 2022/5/19
N2 - Endovascular treatment options of aorto-iliac occlusive disease have emerged, leading to better outcomes in more complex pathology, which typically involves a reconstruction of the aortic bifurcation. The Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) configuration was introduced in 2013, in an attempt to optimize outcomes, when compared to the kissing stent configuration, which was traditionally the preferred endovascular technique for this pathology. CERAB aims to optimize geometry, and with that the arterial flow patterns that are associated with loss of patency. In CERAB, the aortic bifurcation is reconstructed using three balloon-expandable covered stents in a tight connection with each other and with an appropriate wall apposition, thereby minimizing geometrical mismatch (Fig. 1a-c). The reconstruction can be extended on both sides and could be combined with chimney, or parallel, grafts in aortic side branches that need to be preserved. In the current paper, the details of the CERAB technique are described and supported by evidence derived from pre-clinical studies that confirm the more optimal geometry and flow patterns compared to kissing stents. Also, a summary is provided of published clinical evidence, including technical and clinical outcomes of the technique. These data show promising early results, with patency rates in line with those achieved with open surgery, also in patients with extensive disease. Finally, the potential modes of failures and future developments are discussed.
AB - Endovascular treatment options of aorto-iliac occlusive disease have emerged, leading to better outcomes in more complex pathology, which typically involves a reconstruction of the aortic bifurcation. The Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) configuration was introduced in 2013, in an attempt to optimize outcomes, when compared to the kissing stent configuration, which was traditionally the preferred endovascular technique for this pathology. CERAB aims to optimize geometry, and with that the arterial flow patterns that are associated with loss of patency. In CERAB, the aortic bifurcation is reconstructed using three balloon-expandable covered stents in a tight connection with each other and with an appropriate wall apposition, thereby minimizing geometrical mismatch (Fig. 1a-c). The reconstruction can be extended on both sides and could be combined with chimney, or parallel, grafts in aortic side branches that need to be preserved. In the current paper, the details of the CERAB technique are described and supported by evidence derived from pre-clinical studies that confirm the more optimal geometry and flow patterns compared to kissing stents. Also, a summary is provided of published clinical evidence, including technical and clinical outcomes of the technique. These data show promising early results, with patency rates in line with those achieved with open surgery, also in patients with extensive disease. Finally, the potential modes of failures and future developments are discussed.
KW - n/a OA procedure
KW - NLA
UR - http://www.scopus.com/inward/record.url?scp=85130766406&partnerID=8YFLogxK
U2 - 10.52198/22.STI.40.CV1542
DO - 10.52198/22.STI.40.CV1542
M3 - Article
C2 - 35179733
AN - SCOPUS:85130766406
SN - 1090-3941
VL - 40
SP - 263
EP - 270
JO - Surgical technology international
JF - Surgical technology international
ER -