Skip to main navigation Skip to search Skip to main content

The impact of CSF-filled cavities on scalp EEG and its implications

  • Vitória Piai*
  • , Robert Oostenveld
  • , Jan Mathijs Schoffelen
  • , Maria Carla Piastra
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

149 Downloads (Pure)

Abstract

Previous studies have found electroencephalogram (EEG) amplitude and scalp topography differences between neurotypical and neurological/neurosurgical groups, being interpreted at the cognitive level. However, these comparisons are invariably accompanied by anatomical changes. Critical to EEG are the so-called volume currents, which are affected by the spatial distribution of the different tissues in the head. We investigated the effect of cerebrospinal fluid (CSF)-filled cavities on simulated EEG scalp data. We simulated EEG scalp potentials for known sources using different volume conduction models: a reference model (i.e., unlesioned brain) and models with realistic CSF-filled cavities gradually increasing in size. We used this approach for a single source close or far from the CSF-lesion cavity, and for a scenario with a distributed configuration of sources (i.e., a “cognitive event-related potential effect”). The magnitude and topography errors between the reference and lesion models were quantified. For the single-source simulation close to the lesion, the CSF-filled lesion modulated signal amplitude with more than 17% magnitude error and topography with more than 9% topographical error. Negligible modulation was found for the single source far from the lesion. For the multisource simulations of the cognitive effect, the CSF-filled lesion modulated signal amplitude with more than 6% magnitude error and topography with more than 16% topography error in a nonmonotonic fashion. In conclusion, the impact of a CSF-filled cavity cannot be neglected for scalp-level EEG data. Especially when group-level comparisons are made, any scalp-level attenuated, aberrant, or absent effects are difficult to interpret without considering the confounding effect of CSF.

Original languageEnglish
Article numbere14624
JournalPsychophysiology
Volume61
Issue number10
Early online date14 Jun 2024
DOIs
Publication statusPublished - Oct 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • finite element method
  • forward model
  • source imaging
  • stroke
  • volume conduction

Fingerprint

Dive into the research topics of 'The impact of CSF-filled cavities on scalp EEG and its implications'. Together they form a unique fingerprint.

Cite this