The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging

S.M. van der Meer, Michel Versluis, Detlef Lohse, C.T. Chin, A. Bouakaz, N. de Jong

Research output: Contribution to conferencePaperAcademic

110 Downloads (Pure)

Abstract

The resonance frequencies of individual SonoVue/spl trade/ contrast agent bubbles were measured optically by recording the radius-time curves of a single microbubble at 24 different frequencies. For these experiments, the Brandaris 128 fast framing camera was operated in a special segmented mode. The resonance frequencies found for SonoVue/spl trade/ microbubbles are in good agreement with the modified Herring model for coated bubbles indicating that the shell only slightly affects the resonance frequency of this class of contrast bubbles.
Original languageUndefined
Pages343-345
DOIs
Publication statusPublished - 2004
EventIEEE Ultrasonics Symposium 2004 - Montreal, Canada
Duration: 23 Aug 200427 Aug 2004

Conference

ConferenceIEEE Ultrasonics Symposium 2004
CountryCanada
CityMontreal
Period23/08/0427/08/04

Keywords

  • IR-55805

Cite this

van der Meer, S. M., Versluis, M., Lohse, D., Chin, C. T., Bouakaz, A., & de Jong, N. (2004). The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging. 343-345. Paper presented at IEEE Ultrasonics Symposium 2004, Montreal, Canada. https://doi.org/10.1109/ULTSYM.2004.1417735
van der Meer, S.M. ; Versluis, Michel ; Lohse, Detlef ; Chin, C.T. ; Bouakaz, A. ; de Jong, N. / The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging. Paper presented at IEEE Ultrasonics Symposium 2004, Montreal, Canada.
@conference{d4806588f05e434c8cf3aa5e66280414,
title = "The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging",
abstract = "The resonance frequencies of individual SonoVue/spl trade/ contrast agent bubbles were measured optically by recording the radius-time curves of a single microbubble at 24 different frequencies. For these experiments, the Brandaris 128 fast framing camera was operated in a special segmented mode. The resonance frequencies found for SonoVue/spl trade/ microbubbles are in good agreement with the modified Herring model for coated bubbles indicating that the shell only slightly affects the resonance frequency of this class of contrast bubbles.",
keywords = "IR-55805",
author = "{van der Meer}, S.M. and Michel Versluis and Detlef Lohse and C.T. Chin and A. Bouakaz and {de Jong}, N.",
year = "2004",
doi = "10.1109/ULTSYM.2004.1417735",
language = "Undefined",
pages = "343--345",
note = "null ; Conference date: 23-08-2004 Through 27-08-2004",

}

van der Meer, SM, Versluis, M, Lohse, D, Chin, CT, Bouakaz, A & de Jong, N 2004, 'The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging' Paper presented at IEEE Ultrasonics Symposium 2004, Montreal, Canada, 23/08/04 - 27/08/04, pp. 343-345. https://doi.org/10.1109/ULTSYM.2004.1417735

The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging. / van der Meer, S.M.; Versluis, Michel; Lohse, Detlef; Chin, C.T.; Bouakaz, A.; de Jong, N.

2004. 343-345 Paper presented at IEEE Ultrasonics Symposium 2004, Montreal, Canada.

Research output: Contribution to conferencePaperAcademic

TY - CONF

T1 - The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging

AU - van der Meer, S.M.

AU - Versluis, Michel

AU - Lohse, Detlef

AU - Chin, C.T.

AU - Bouakaz, A.

AU - de Jong, N.

PY - 2004

Y1 - 2004

N2 - The resonance frequencies of individual SonoVue/spl trade/ contrast agent bubbles were measured optically by recording the radius-time curves of a single microbubble at 24 different frequencies. For these experiments, the Brandaris 128 fast framing camera was operated in a special segmented mode. The resonance frequencies found for SonoVue/spl trade/ microbubbles are in good agreement with the modified Herring model for coated bubbles indicating that the shell only slightly affects the resonance frequency of this class of contrast bubbles.

AB - The resonance frequencies of individual SonoVue/spl trade/ contrast agent bubbles were measured optically by recording the radius-time curves of a single microbubble at 24 different frequencies. For these experiments, the Brandaris 128 fast framing camera was operated in a special segmented mode. The resonance frequencies found for SonoVue/spl trade/ microbubbles are in good agreement with the modified Herring model for coated bubbles indicating that the shell only slightly affects the resonance frequency of this class of contrast bubbles.

KW - IR-55805

U2 - 10.1109/ULTSYM.2004.1417735

DO - 10.1109/ULTSYM.2004.1417735

M3 - Paper

SP - 343

EP - 345

ER -

van der Meer SM, Versluis M, Lohse D, Chin CT, Bouakaz A, de Jong N. The resonance frequency of SonoVue (tm) as observed by high-speed optical imaging. 2004. Paper presented at IEEE Ultrasonics Symposium 2004, Montreal, Canada. https://doi.org/10.1109/ULTSYM.2004.1417735