TY - JOUR
T1 - Thin Composite-Wire-Strut Zotarolimus-Eluting Stents Versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years
AU - Buiten, Rosaly A.
AU - Ploumen, Eline H.
AU - Zocca, Paolo
AU - Doggen, Carine J.M.
AU - Jessurun, Gillian A.J.
AU - Schotborgh, Carl E.
AU - Roguin, Ariel
AU - Danse, Peter W.
AU - Benit, Edouard
AU - Aminian, Adel
AU - van Houwelingen, K. Gert
AU - Schramm, Alexander R.
AU - Stoel, Martin G.
AU - Somi, Samer
AU - Hartmann, Marc
AU - Linssen, Gerard C.M.
AU - von Birgelen, Clemens
PY - 2020/5/11
Y1 - 2020/5/11
N2 - Objectives: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis. Background: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates. Methods: A total of 2,488 all-comer patients were treated at 7 coronary intervention centers in Belgium, Israel, and the Netherlands. The main endpoint, TVF, was a composite of safety (cardiac death or target vessel–related myocardial infarction) and efficacy (clinically indicated target vessel revascularization). Two-year follow-up data were analyzed using Kaplan-Meier methods. Results: Two-year follow-up data were available for 2,460 of 2,488 patients (98.9%). TVF occurred in 93 of 1,243 patients (7.6%) assigned to ZES versus 87 of 1,245 patients (7.1%) assigned to SES (log-rank p = 0.66). There was no significant between-stent difference in individual components of this endpoint. The incidence of definite-or-probable stent thrombosis was low for both treatment arms (0.4% vs. 1.1%; log-rank p = 0.057). In patients stented in small vessels, there was no between-stent difference (TVF 8.2% vs. 8.7% [log-rank p = 0.75], target lesion revascularization 4.0% vs. 4.4% [log-rank p = 0.77]). Conclusions: At 2-year follow-up, the novel thin composite-wire-strut durable-polymer Resolute Onyx ZES showed in all-comers similar safety and efficacy compared with the ultrathin cobalt-chromium-strut biodegradable-polymer Orsiro SES. The analysis of patients who were treated in small vessels also suggested no advantage for either stent.
AB - Objectives: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis. Background: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates. Methods: A total of 2,488 all-comer patients were treated at 7 coronary intervention centers in Belgium, Israel, and the Netherlands. The main endpoint, TVF, was a composite of safety (cardiac death or target vessel–related myocardial infarction) and efficacy (clinically indicated target vessel revascularization). Two-year follow-up data were analyzed using Kaplan-Meier methods. Results: Two-year follow-up data were available for 2,460 of 2,488 patients (98.9%). TVF occurred in 93 of 1,243 patients (7.6%) assigned to ZES versus 87 of 1,245 patients (7.1%) assigned to SES (log-rank p = 0.66). There was no significant between-stent difference in individual components of this endpoint. The incidence of definite-or-probable stent thrombosis was low for both treatment arms (0.4% vs. 1.1%; log-rank p = 0.057). In patients stented in small vessels, there was no between-stent difference (TVF 8.2% vs. 8.7% [log-rank p = 0.75], target lesion revascularization 4.0% vs. 4.4% [log-rank p = 0.77]). Conclusions: At 2-year follow-up, the novel thin composite-wire-strut durable-polymer Resolute Onyx ZES showed in all-comers similar safety and efficacy compared with the ultrathin cobalt-chromium-strut biodegradable-polymer Orsiro SES. The analysis of patients who were treated in small vessels also suggested no advantage for either stent.
KW - clinical trial
KW - drug-eluting stents
KW - percutaneous coronary intervention
UR - http://www.scopus.com/inward/record.url?scp=85083741692&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2020.01.230
DO - 10.1016/j.jcin.2020.01.230
M3 - Article
C2 - 32381186
AN - SCOPUS:85083741692
VL - 13
SP - 1100
EP - 1109
JO - JACC : cardiovascular interventions
JF - JACC : cardiovascular interventions
SN - 1936-8798
IS - 9
ER -