T1 - Thin, very thin, or ultrathin-strut biodegradable or durable polymer-coated drug-eluting stents
AU - Buiten, Rosaly A.
AU - Zocca, Paolo
AU - von Birgelen, Clemens
PY - 2020/11/1
Y1 - 2020/11/1
N2 - PURPOSE OF REVIEW: The current article will review recently published clinical studies that evaluate very thin or ultrathin-strut drug-eluting stents (DES), focusing on major randomized clinical trials in broad patient populations. RECENT FINDINGS: Multiple randomized trials recently assessed the clinical performance of novel very thin to ultrathin-strut DES. Most randomized trials established noninferiority of the novel device. To date, only one major randomized clinical trial (i.e., BIOFLOW V) showed superiority of an ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent over a very thin-strut durable polymer-coated everolimus-eluting stent in a relatively broad patient population. There are signals that the same ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent may improve clinical outcome in specific patient populations. For example, in the randomized BIOSTEMI trial, 1-year superiority of the ultrathin-strut DES was found in patients presenting with an acute ST-segment elevation myocardial infarction. Yet, substudies of large randomized trials that assessed patients with small-vessel treatment showed equivocal results. SUMMARY: Although two randomized trials showed advantages for ultrathin-strut DES, other clinical trials provided no significant evidence that ultrathin-strut DES improve clinical outcome. The question whether ultrathin-strut DES may reduce the repeat revascularization risk following implantation in small vessels is a matter of further debate and future research.
AB - PURPOSE OF REVIEW: The current article will review recently published clinical studies that evaluate very thin or ultrathin-strut drug-eluting stents (DES), focusing on major randomized clinical trials in broad patient populations. RECENT FINDINGS: Multiple randomized trials recently assessed the clinical performance of novel very thin to ultrathin-strut DES. Most randomized trials established noninferiority of the novel device. To date, only one major randomized clinical trial (i.e., BIOFLOW V) showed superiority of an ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent over a very thin-strut durable polymer-coated everolimus-eluting stent in a relatively broad patient population. There are signals that the same ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent may improve clinical outcome in specific patient populations. For example, in the randomized BIOSTEMI trial, 1-year superiority of the ultrathin-strut DES was found in patients presenting with an acute ST-segment elevation myocardial infarction. Yet, substudies of large randomized trials that assessed patients with small-vessel treatment showed equivocal results. SUMMARY: Although two randomized trials showed advantages for ultrathin-strut DES, other clinical trials provided no significant evidence that ultrathin-strut DES improve clinical outcome. The question whether ultrathin-strut DES may reduce the repeat revascularization risk following implantation in small vessels is a matter of further debate and future research.
KW - n/a OA procedure
UR - http://www.scopus.com/inward/record.url?scp=85092802505&partnerID=8YFLogxK
U2 - 10.1097/HCO.0000000000000786
DO - 10.1097/HCO.0000000000000786
M3 - Article
C2 - 32852343
AN - SCOPUS:85092802505
SN - 0268-4705
VL - 35
SP - 705
EP - 711
JO - Current Opinion in Cardiology
JF - Current Opinion in Cardiology
IS - 6
ER -