Toward spectral-domain optical coherence tomography on a silicon chip

B.I. Akça, B. Povazay, A. Alex, Kerstin Worhoff, R.M. de Ridder, W. Drexler, Markus Pollnau

    Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademic

    Abstract

    In-vivo imaging was demonstrated with a depth range of 1.4 mm and axial resolution of 7.5 µm by using a miniaturized spectral-domain optical coherence tomography system comprising an integrated spectrometer and a beam splitter.
    Original languageUndefined
    Title of host publicationSPIE/OSA European Conferences on Biomedical Optics, ECBO 2013
    Place of PublicationBellingham, WA, USA
    PublisherSPIE
    PagesPage 32-Paper EM3B.1
    Number of pages3
    ISBN (Print)not assigned
    Publication statusPublished - May 2013
    EventEuropean Conferences on Biomedical Optics, ECBO 2013 - Munich, Germany
    Duration: 12 May 201316 May 2013

    Publication series

    NameConference Program
    PublisherSPIE

    Conference

    ConferenceEuropean Conferences on Biomedical Optics, ECBO 2013
    Abbreviated titleECBO
    CountryGermany
    CityMunich
    Period12/05/1316/05/13

    Keywords

    • IOMS-PIT: PHOTONICS INTEGRATION TECHNOLOGY
    • Optical Coherence Tomography
    • IR-86212
    • Integrated Optics devices
    • METIS-303962
    • EWI-23353

    Cite this

    Akça, B. I., Povazay, B., Alex, A., Worhoff, K., de Ridder, R. M., Drexler, W., & Pollnau, M. (2013). Toward spectral-domain optical coherence tomography on a silicon chip. In SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013 (pp. Page 32-Paper EM3B.1). (Conference Program). Bellingham, WA, USA: SPIE.
    Akça, B.I. ; Povazay, B. ; Alex, A. ; Worhoff, Kerstin ; de Ridder, R.M. ; Drexler, W. ; Pollnau, Markus. / Toward spectral-domain optical coherence tomography on a silicon chip. SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013. Bellingham, WA, USA : SPIE, 2013. pp. Page 32-Paper EM3B.1 (Conference Program).
    @inproceedings{d2268f0000ae435f991d706c330e4d0a,
    title = "Toward spectral-domain optical coherence tomography on a silicon chip",
    abstract = "In-vivo imaging was demonstrated with a depth range of 1.4 mm and axial resolution of 7.5 µm by using a miniaturized spectral-domain optical coherence tomography system comprising an integrated spectrometer and a beam splitter.",
    keywords = "IOMS-PIT: PHOTONICS INTEGRATION TECHNOLOGY, Optical Coherence Tomography, IR-86212, Integrated Optics devices, METIS-303962, EWI-23353",
    author = "B.I. Ak{\cc}a and B. Povazay and A. Alex and Kerstin Worhoff and {de Ridder}, R.M. and W. Drexler and Markus Pollnau",
    note = "Paper EM3B.1",
    year = "2013",
    month = "5",
    language = "Undefined",
    isbn = "not assigned",
    series = "Conference Program",
    publisher = "SPIE",
    pages = "Page 32--Paper EM3B.1",
    booktitle = "SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013",
    address = "United States",

    }

    Akça, BI, Povazay, B, Alex, A, Worhoff, K, de Ridder, RM, Drexler, W & Pollnau, M 2013, Toward spectral-domain optical coherence tomography on a silicon chip. in SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013. Conference Program, SPIE, Bellingham, WA, USA, pp. Page 32-Paper EM3B.1, European Conferences on Biomedical Optics, ECBO 2013, Munich, Germany, 12/05/13.

    Toward spectral-domain optical coherence tomography on a silicon chip. / Akça, B.I.; Povazay, B.; Alex, A.; Worhoff, Kerstin; de Ridder, R.M.; Drexler, W.; Pollnau, Markus.

    SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013. Bellingham, WA, USA : SPIE, 2013. p. Page 32-Paper EM3B.1 (Conference Program).

    Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademic

    TY - GEN

    T1 - Toward spectral-domain optical coherence tomography on a silicon chip

    AU - Akça, B.I.

    AU - Povazay, B.

    AU - Alex, A.

    AU - Worhoff, Kerstin

    AU - de Ridder, R.M.

    AU - Drexler, W.

    AU - Pollnau, Markus

    N1 - Paper EM3B.1

    PY - 2013/5

    Y1 - 2013/5

    N2 - In-vivo imaging was demonstrated with a depth range of 1.4 mm and axial resolution of 7.5 µm by using a miniaturized spectral-domain optical coherence tomography system comprising an integrated spectrometer and a beam splitter.

    AB - In-vivo imaging was demonstrated with a depth range of 1.4 mm and axial resolution of 7.5 µm by using a miniaturized spectral-domain optical coherence tomography system comprising an integrated spectrometer and a beam splitter.

    KW - IOMS-PIT: PHOTONICS INTEGRATION TECHNOLOGY

    KW - Optical Coherence Tomography

    KW - IR-86212

    KW - Integrated Optics devices

    KW - METIS-303962

    KW - EWI-23353

    M3 - Conference contribution

    SN - not assigned

    T3 - Conference Program

    SP - Page 32-Paper EM3B.1

    BT - SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013

    PB - SPIE

    CY - Bellingham, WA, USA

    ER -

    Akça BI, Povazay B, Alex A, Worhoff K, de Ridder RM, Drexler W et al. Toward spectral-domain optical coherence tomography on a silicon chip. In SPIE/OSA European Conferences on Biomedical Optics, ECBO 2013. Bellingham, WA, USA: SPIE. 2013. p. Page 32-Paper EM3B.1. (Conference Program).